Specifications
Table Of Contents
30 www.goodmanmfg.com SS-DSXC16
SS-DSXC16 www.goodmanmfg.com 31
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
⚠ Warning
High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
Wiring Diagram
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
HIGH VOLTAGE
FIELD
OPTIONAL HIGH
VOLTAGE
OPTIONAL LOW
VOLTAGE
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BL/PK ---------- BLUE/PINK STRIPE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
YL/PK ---------- YELLOW/PINK STRIPE
1
3
46
E51
E16
PU
RD
(LOW)
BR
RELAY
RELAY
RELAY
HERM
COM
START
RUN
E13
L2 OUT
L2
L1
E10
R
C
START
E5
E8
CAP COM
CH
E21
E17
START RLY
UC BOARD
FUSE
O
L
R
C
W1
Y1
E2
Y2
FAN
RUN
1
2
1
2
R
C
E25
E29
E28
E26
E9
E23
E22
E24
HIGH
RVS LPCO
HPCO
OAS
RD
BK
RD
RD
BK
YL
GND
LOW VOLTAGE
BARRIER
BL/PK
BK
YL/PK
YL/PK
RD
BK
BK
BK
BL/PK
RCCF
C
R
S
AUX
MAIN
COMP
CS
Y2
C
BK
YL
RD
CONTROL BOX
L1
L2
K2
C
R
S
COMP
R
S
HERM
C
PSC FAN MOTOR
C
UC CONTROL
HERM
CAP
COM
C
HIGH
LOW
K4
K3
RUN CAPACITOR
K5
L
Y2
Y1
C
L (OPTIONAL)
Y2
Y1
C
LEGACY INDOOR THERMOSTAT
C
R
2
1
C
R
2
1
R
R
C
R
COMMUNICATING INDOOR THERMOSTAT
TO INDOOR
COMMUNICATING PCB
FAN
CAP
0140R00418 - B
FROM
OUTDOOR
UNIT
FROM
OUTDOOR
UNIT
RES
2
5
1
SR
SC
OPTIONAL HARD START
CM
1
2
5
SC
SR
OPTIONAL HARD START
CH
BK
RD
RD
GR/YL
CCH
CHS
RD
BK
RD
CHS
YL
BK
RD
YL
PU
BL
RD
RELAY
RELAY
INDOOR POWER SUPPLY 24V AC
COMPONENT CODE
C --------------- CONTACTOR
CH ------------- CRANKCASE HEATER
CHS------------ CRANKCASE HEATER SWITCH
CM ------------ CONDENSER FAN MOTOR
COMP -------- COMPRESSOR
CS ------------- COMPRESSOR SOLENOID
DT--------------- DISCHARGE THERMOSTAT
HPS ----------- HIGH PRESSURE SWITCH
IO -------------- INTERNAL OVERLOAD
LPS ---------- LOW PRESSURE SWITCH
OAS ----------- OUTDOOR AIR SENSOR
OCS------------OUTDOOR COIL TEMP SENSOR
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
RVS ----------- REVERSING VALVE SOLENOID
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
HPS
DT
SEE NOTE 3
NOTES:
1. USE COPPER SUPPLY WIRES ONLY.
2. USE 40VA TRANSFORMER MINIMUM FOR SYSTEM
3. IF DT IS NOT PRESENT, HPS BL/PK WIRE GOES DIRECTLY
TO TERMINAL E29.
4. CONTROLS SHOWN WITH THERMOSTAT IN "OFF" POSITION.
5. COMMON SIDE OF 24VAC CONTROL CIRCUIT MUST BE
GROUNDED.
6. USE N.E.C. CLASS 2 WIRES.
7. COMPRESSOR WIRE TO BE ROUTED THROUGH CENTER OF
CURRENT SENSOR BEFORE CONNECTING TO R TERMINAL
SEE NOTE 1
230 VAC SUPPLY
L1
L2
SEE NOTE 1
TO FIELD LOW
VOLTAGE
CONTROL WIRES.
SEE NOTES 2 AND 5
LPS
AUX
MAIN
BK
(HIGH)
BK
O
L
R
C
W1
Y1
E2
Y2
1
2
LPS
E22
E23
E9
E26
E7
E1
HPS
OAS
DT
E28
HIGH VOLTAGE AREA
LOW VOLTAGE AREA
H
F
C
BR
YL
PU
E29
IO
E21
CS
NOTE 1
E7
OAT
OCT
E1
SEE NOTE 6
SEE NOTE 6
SEE NOTE 6
SEE NOTE 6
NOTE: SEE INSTALLATION MANUAL FOR
R-C WIRING OF AIR CONDITIONER CONTROL
INDOOR POWER SUPPLY 24V AC
SEE NOTE 7