Specifications

6 www.goodmanmfg.com SS-GCVC96
SS-GCVC96 www.goodmanmfg.com 7
Airflow Data (cont.)
Notes
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
GCVC960804CNA
Cooling Speeds
( @ .1" - .8" w.c. ESP)
GCVC960804CNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 45 - 75°F)
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Rise
(°F)
A
Minus 10% 753 500
A
Minus 10% 1,111 800
n/a
Minus 5% 795 528 Minus 5% 1,172 845
n/a
Normal 837 556 Normal 1,234 889
n/a
Plus 5% 879 584 Plus 5% 1,296 933
55
Plus 10% 921 612 Plus 10% 1,357 978
52
B
Minus 10% 920 643
B
Minus 10% 1,193 850
n/a
Minus 5% 971 678 Minus 5% 1,259 897
n/a
Normal 1,022 714 Normal 1,325 944
54
Plus 5% 1,073 750 Plus 5% 1,391 991
51
Plus 10% 1,124 785 Plus 10% 1,458 1,038
49
C
Minus 10% 1,085 754
C
Minus 10% 1,298 917
55
Minus 5% 1,146 796 Minus 5% 1,370 968
52
Normal 1,206 838 Normal 1,442 1,019
49
Plus 5% 1,266 880 Plus 5% 1,514 1,070
47
Plus 10% 1,327 922 Plus 10% 1,586 1,121
45
D
Minus 10% 1,328 892
D
Minus 10% 1,375 961
52
Minus 5% 1,401 941 Minus 5% 1,452 1,015
49
Normal 1,475 991 Normal 1,528 1,068
47
Plus 5% 1,549 1,041 Plus 5% 1,604 1,121
n/a
Plus 10% 1,623 1,090 Plus 10% 1,681 1,175
n/a
GCVC961005CNA
Cooling Speeds
( @ .1" - .8" w.c. ESP)
GCVC961005CNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 45 - 75°F)
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Tap Adjust
High-Stage
CFM
Low-Stage
CFM
Rise
(°F)
A
Minus 10% 706 472
A
Minus 10% 1,583 1,088
56
Minus 5% 745 498 Minus 5% 1,671 1,149
53
Normal 784 524 Normal 1,759 1,209
51
Plus 5% 823 550 Plus 5% 1,847 1,269
48
Plus 10% 862 576 Plus 10% 1,935 1,330
46
B
Minus 10% 970 670
B
Minus 10% 1,617 1,124
55
Minus 5% 1,024 707 Minus 5% 1,707 1,187
52
Normal 1,078 744 Normal 1,797 1,249
49
Plus 5% 1,132 781 Plus 5% 1,887 1,311
47
Plus 10% 1,186 818 Plus 10% 1,977 1,374
45
C
Minus 10% 1,249 834
C
Minus 10% 1,656 1,149
54
Minus 5% 1,319 881 Minus 5% 1,748 1,213
51
Normal 1,388 927 Normal 1,840 1,277
48
Plus 5% 1,457 973 Plus 5% 1,932 1,341
46
Plus 10% 1,527 1,020 Plus 10% 2,024 1,405
44
D
Minus 10% 1,589 1,067
D
Minus 10% 1,693 1,170
53
Minus 5% 1,678 1,126 Minus 5% 1,787 1,235
50
Normal 1,766 1,185 Normal 1,881 1,300
47
Plus 5% 1,854 1,244 Plus 5% 1,975 1,365
45
Plus 10% 1,943 1,304 Plus 10% 2,069 1,430
n/a