Service Manual
PRODUCT IDENTIFICATION
8
MODEL: GCVC96 REV AA
Equipment Type Goodman Brand Residential Gas Furnace
Heating Stages Two
Cooling Stages Two
Control Type ClimateTalk
™ or Conventional 24 Volt
Blower Motor Type 4 Wire Variable Speed ECM
GCV C9 6
0403BN 0603BN 0803BN 0804CN 1005CN 1205DN
Installation Positions CF, Hor L/R CF, Hor L/R CF, Hor L/R CF, Hor L/R CF, Hor L/R CF, Hor L/R
BTUH Input Low Fire (X 1000) 30 45 60 60 75 90
BTUH Input High Fire (X 1000) 40 60 80 80 100 120
A/C Capable Tons 1.5 - 3 1.5 - 3 2 - 4 2 - 4 2 - 5 2 - 5
Cabinet Hight " 34.5 34.5 34.5 34.5 34.5
Cabinet Width " 17.5 17.5 21 21 24.5
Heating CFM @ 100% Firing Rate 1059 950 1146 1325 1797 1827
Draft Inducer
Gas Valve
24 VAC Heating Inputs
24 VAC Cooling Inputs
Primary Heat Exchanger
Accessory Terminals
Gas Line Entry
Revision Attributes
Left or Right
First revision of 34.5" modulating counter flow furnace
Two Speed
Two Stage
W1 / W2
Y1 / Y2
Aluminized Steel
EAC terminal, Field Powered HUM IN / HUM OUT terminals, Single Hum terminal
powered simultaneously with draft inducer, AUX circuit
MODEL: ACVC96 REV AA
Equipment Type Amana Brand Residential Gas Furnace
Heating Stages Two
Cooling Stages Two
Control Type ClimateTalk
™ or Conventional 24 Volt
Blower Motor Type 4 Wire Variable Speed ECM
ACVC96
0403BN 0603BN 0803BN 0804CN 1005CN 1205DN
Installation Positions CF, Hor L/R CF, Hor L/R CF, Hor L/R CF, Hor L/R CF, Hor L/R CF, Hor L/R
BTUH Input Low Fire (X 1000) 30 45 60 60 75 90
BTUH Input High Fire (X 1000) 40 60 80 80 100 120
A/C Capable Tons 1.5 - 3 1.5 - 3 2 - 4 2 - 4 2 - 5 2 - 5
Cabinet Hight " 34.5 34.5 34.5 34.5 34.5
Cabinet Width " 17.5 17.5 21 21 24.5
Heating CFM @ 100% Firing Rate 1059 950 1146 1325 1797 1827
Draft Inducer
Gas Valve
24 VAC Heating Inputs
24 VAC Cooling Inputs
Primary Heat Exchanger
Accessory Terminals
Gas Line Entry
Revision Attributes
Left or Right
First revision of 34.5" modulating counter flow furnace
Two Speed
Two Stage
W1 / W2
Y1 / Y2
Stainless Steel
EAC terminal, Field Powered HUM IN / HUM OUT terminals, Single Hum terminal
powered simultaneously with draft inducer, AUX circuit
MODEL: GMVC96 REV AA
Equipment Type Goodman Brand Residential Gas Furnace
Heat ing St ages Two
Cooling Stages Two
Control Type ClimateTalk
™ or Conventional 24 Volt
Blower Motor Type 4 Wire Variable Speed ECM
GMV C 96
0403BN 0603BN 0803BN 0804CN 1005CN 1005DN 1205DN
Installation Positions
UF, Hor L/RUF, Hor L/RUF, Hor L/RUF, Hor L/RUF, Hor L/RUF, Hor L/RUF, Hor L/R
BTUH Input Low Fire (X 1000)
30 45 60 60 75 75 90
BTUH Input High Fire (X 1000)
40 60 80 80 100 100 120
A/C Capable Tons
1.5 - 31.5 - 31.5 - 32 - 41.5 - 52 - 5 2 - 5
Cabinet Hight "
34.5 34.5 34.5 34.5 34.5 34.5 34.5
Cabinet Width "
17.5 17.5 17.5 21 21 24.5 24.5
Heating CFM @ 100% Firing Rate
553 1059 1316 1337 1870 1940 1940
Draft Inducer
Two Speed
Gas Valv e
24 VAC Heating Inputs
24 VAC Cooling Inputs
Primary Heat Exchanger
Accessory Terminals
Gas Line Entry
Revision Attributes
First revision of 34.5" two stage communicating capable up flow furnace
Two Stage
W1 / W2
Y1 / Y2
Aluminized Steel
EAC terminal, Field Powered HUM IN / HUM OUT terminals, Single Hum terminal powered
simultaneously with draft inducer, AUX circuit
Left or Right
MODEL: AMVC96 REV AA
Equipment Type Amana Brand Residential Gas Furnace
Heat ing Stages Two
Cooling Stages Two
Control Type ClimateTalk
™ or Conventional 24 Volt
Blower Motor Type 4 Wire Variable Speed ECM
AMVC96
0403BN 0603BN 0803BN 0804CN 1005CN 1005DN 1205DN
Installation Positions
UF, Hor L/R UF, Hor L/R UF, Hor L/R UF, Hor L/R UF, Hor L/R UF, Hor L/R UF, Hor L/R
BTUH Input Low Fire (X 1000)
30 45 60 60 75 75 90
BTUH Input High Fire (X 1000)
40 60 80 80 100 100 120
A/C Capable Tons
1.5 - 3 1.5 - 3 1.5 - 3 2 - 4 1.5 - 5 2 - 5 2 - 5
Cabinet Hight "
34.5 34.5 34.5 34.5 34.5 34.5 34.5
Cabinet Width "
17.5 17.5 17.5 21 21 24.5 24.5
Heating CFM @ 100% Firing Rate
553 1059 1316 1337 1870 1940 1940
Draft Inducer
Two Speed
Gas Valve
24 VAC Heating Inputs
24 VAC Cooling Inputs
Primary Heat Exchanger
Accessory Terminals
Gas Line Entry
Revision Attributes
First revision of 34.5" two stage communicating capable up flow furnace
Two Stage
W1 / W2
Y1 / Y2
Stainless Steel
EAC terminal, Field Powered HUM IN / HUM OUT terminals, Single Hum terminal powered
simultaneously with draft inducer, AUX circuit
Left or Right