Technical Information

FURNACE SPECIFICATIONS
5
*CVC96
0403BNA
*CVC96
0603BNA
*CVC96
0804CNA
*CVC96
1005CNA
*CVC96
1205DNA
High Fire Input¹ 40,000 60,000 80,000 100,000 120,000
High Fire Output¹ 38,400 57,600 76,800 96,000 115,200
Low-Fire Steady-State Input¹ 28,000 42,000 56,000 70,000 84,000
Low-Fire Steady-State Output¹ 26,880 40,320 53,760 67,200 80,640
AFUE² 9696969696
Temperature Rise Range (°F) 20 - 50 35 - 65 25 - 55 45 - 75 35 - 65
Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3"
No. of Burners 2 3 4 5 6
Circulator Blower
Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 1.5 - 4 2 - 5 2 - 5
Size (D x W) 10" x 8" 11" x 8" 11" x 10" 11" x 10" 11" x 11"
Horsepower @ 1075 RPM
½½¾
11
Speed VSECM VSECM VSECM VSECM VSECM
Filter Size (in²)
Permanent 488 512 853 711 1,024
Disposable 244 256 427 356 512
Electrical Data
Min. Circuit Ampacity 7.8 7.8 10.6 14.4 14.4
Max. Overcurrent Device (amps) 15 15 15 20 20
Shipping Weight (lbs)
¹ Natural Gas BTU/h
²
³
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
and noise issues.
may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility
clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
116 119 143 145 158