Specifications
Product SPecificationS
6 www.goodmanmfg.com SS-GMVM97
SS-GMVM97 www.goodmanmfg.com 7
GMVM97 airFlow data
GMVM970603BNA
GMVM970603BNA
CFM
CFM
CFM
A
539 358
A
858 n/a
Normal 599 398 Normal 953 n/a
659 438 1,048 51
B
735 501
B
953 n/a
Normal 817 557 Normal 1,059 51
899 613 1,165 46
C
906 626
C
1,042 52
Normal 1,007 696 Normal 1,158 47
1,108 766 1,274 42
D
1,091 729
D
1,134 48
Normal 1,212 810 Normal 1,260 43
1,333 891 1,386 39
GMVM970803BNA
GMVM970803BNA
CFM
CFM
CFM
A
566 363
A
1,082 n/a
Normal 629 403 Normal 1,202 60
692 443 1,322 54
B
725 486
B
1,184 n/a
Normal 806 540 Normal 1,316 55
887 594 1,448 50
C
921 635
C
1,250 57
Normal 1,023 705 Normal 1,389 52
1,125 776 1,528 47
D
1,107 737
D
1,256 57
Normal 1,230 819 Normal 1,396 51
1,353 901 1,536 47
GMVM970804CNA
GMVM970804CNA
CFM
CFM
CFM
A
710 462
A
1,105 n/a
Normal 789 513 Normal 1,228 n/a
868 564 1,351 53
B
870 594
B
1,203 n/a
Normal 967 660 Normal 1,337 54
1,064 726 1,471 49
C
1,064 712
C
1,287 n/a
Normal 1,182 791 Normal 1,430 50
1,300 870 1,573 46
D
1,238 822
D
1,364 53
Normal 1,375 913 Normal 1,516 47
1,513 1,004 1,668 43
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
• For most jobs, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.