Condensing Unit & Heat Pump R410A Service Manual
82
SYSTEM OPERATION
EXPANSION VALVE/CHECK VALVE ASSEMBLY IN
COOLING OPERATION
EXPANSION VALVE/CHECK VALVE ASSEMBLY IN
HEATING OPERATION
Most expansion valves used in current Amana Heat Pump products use an internally checked expansion valve. This type
of expansion valve does not require an external check valve as shown above.
Restrictor Orice Assy in Cooling Operation
Restrictor Orice Assy in Heating Operation
In the cooling mode, the orice is pushed into its seat,
forcing refrigerant to ow through the metered hole in the
center of the orice.
In the heating mode, the orice moves back o its seat,
allowing refrigerant to ow unmetered around the outside of
the orice.