COOLING PERFORMANCE DATA
GSX130301DA
MODEL: GSX130301D* / CA*F3030*6D*
EXPANDED PERFORMANCE DAT
A
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67715963677159636771
MBh 25.8 26.4 28.2 30.1 25.2 25.8 27.5 29.4 24.6 25.1 26.9 28.7 24.0 24.5 26.2 28.0 22.8 23.3 24.9 26.6 21.1 21.6 23.1 24.7
S/T 0.84 0.79 0.64 0.48 0.87 0.81 0.66 0.50 0.89 0.83 0.68 0.51 0.92 0.86 0.70 0.52 0.95 0.89 0.73 0.54 0.96 0.90 0.73 0.55
Delta T22211814222118152221181522 21 18152221181420191714
919 KW 2.00 2.04 2.10 2.16 2.15 2.19 2.26 2.33 2.27 2.32 2.39 2.47 2.39 2.44 2.51 2.59 2.48 2.54 2.62 2.70 2.57 2.62 2.71 2.79
AMPS 6.9 7.0 7.2 7.5 7.4 7.6 7.8 8.1 8.1 8.3 8.5 8.9 8.6 8.8 9.1 9.5 9.2 9.4 9.7 10.1 9.7 10.0 10.3 10.7
HI PR 241 259 274 285 270 291 307 320 307 331 349 364 350 377 398 415 394 424 447 467 435 468 494 516
LO PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162
MBh 28.0 28.6 30.5 32.6 27.3 27.9 29.8 31.9 26.7 27.2 29.1 31.1 26.0 26.6
28.4
30.4 24.7 25.3 27.0 28.8 22.9 23.4 25.0 26.7
S/T 0.87 0.81 0.66 0.50 0.90 0.84 0.69 0.51 0.92 0.87 0.70 0.53 0.95 0.89
0.73
0.54 0.99 0.93 0.75 0.56 1.00 0.93 0.76 0.57
Delta T21201814222118142221181422 21
18
14 21 20 18 14 20 19 17 13
80 1050 KW 2.05 2.09 2.15 2.22 2.20 2.24 2.31 2.38 2.33 2.38 2.45 2.53 2.45 2.50
2.58
2.66 2.54 2.60 2.68 2.77 2.63 2.69 2.77 2.86
AMPS 7.0 7.2 7.5 7.7 7.6 7.8 8.1 8.4 8.3 8.5 8.8 9.1 8.9 9.1
9.4
9.8 9.5 9.7 10.0 10.4 10.0 10.3 10.6 11.0
HI PR 248 267 282 294 279 300 317 330 317 341 360 375 361 388
410
428 406 437 461 481 448 483 510 532
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133
145
154 131 139 152 162 135 144 157 167
MBh 28.8 29.4 31.4 33.6 28.1 28.7 30.7 32.8 27.5 28.1 30.0 32.1 26.8 27.4 29.3 31.3 25.5 26.0 27.8 29.7 23.6 24.1 25.7 27.5
S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.80 0.60
Delta T20201714212017142120171421 20 17142020171418191613
1181 KW 2.06 2.10 2.17 2.23 2.21 2.26 2.33 2.40 2.35 2.40 2.47 2.55 2.46 2.52 2.60 2.68 2.56 2.62 2.70 2.79 2.65 2.71 2.80 2.89
AMPS 7.1 7.3 7.5 7.8 7.7 7.9 8.1 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.5 9.9 9.5 9.8 10.1 10.5 10.1 10.4 10.7 11.1
HI PR 251 270 285 297 281 303 320 333 320 344 364 379 364 392 414 432 410 441 466 486 453 487 515 537
LO PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169
MBh 26.3 26.8 28.0 29.9 25.7 26.1 27.4 29.2 25.0 25.5 26.7 28.5 24.4 24.9 26.1 27.8 23.2 23.7 24.8 26.4 21.5 21.9 23.0 24.5
S/T 0.88 0.85 0.76 0.62 0.91 0.88 0.79 0.64 0.93 0.90 0.81 0.66 0.96 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 0.97 0.88 0.71
Delta T23232119232322192323221924 23 22192323221922212017
919 KW 2.02 2.06 2.12 2.18 2.16 2.21 2.27 2.34 2.29 2.34 2.41 2.49 2.41 2.46 2.53 2.62 2.50 2.56 2.64 2.72 2.59 2.64 2.73 2.82
AMPS 6.9 7.1 7.3 7.6 7.5 7.7 7.9 8.2 8.1 8.3 8.6 8.9 8.7 8.9 9.2 9.6 9.3 9.5 9.8 10.2 9.8 10.1 10.4 10.8
HI PR 243 262 276 288 273 294 310 323 310 334 353 368 353 380 402 419 398 428 452 471 439 473 499 521
LO PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 159 133 141 154 164
MBh 28.5 29.0 30.4 32.4 27.8 28.3 29.7 31.7 27.1 27.7 29.0 30.9 26.5 27.0 28.3 30.1 25.1 25.6 26.8 28.6 23.3 23.7 24.9 26.5
S/T 0.91 0.88 0.79 0.64 0.94 0.91 0.82 0.67 0.97 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74
Delta T23222118232321182323211823 23 22192222211820212017
85 1050 KW 2.06 2.10 2.17 2.23 2.21 2.26 2.33 2.40 2.35 2.40 2.47 2.55 2.46 2.52 2.60 2.68 2.56 2.62 2.70 2.79 2.65 2.71 2.80 2.89
AMPS 7.1 7.3 7.5 7.8 7.7 7.9 8.1 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.5 9.9 9.5 9.8 10.1 10.5 10.1 10.4 10.7 11.1
HI PR 251 270 285 297 281 303 320 333 320 344 364 379 364 392 414 432 410 441 466 486 453 487 515 537
LO PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169
MBh 29.3 29.9 31.3 33.4 28.6 29.2 30.6 32.6 27.9 28.5 29.8 31.8 27.3 27.8 29.1 31.1 25.9 26.4 27.7 29.5 24.0 24.5 25.6 27.3
S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.95 0.77
Delta T22212018222220182222211821 22 21182021201819191916
1181 KW 2.08 2.12 2.18 2.25 2.23 2.28 2.35 2.42 2.37 2.42 2.49 2.57 2.48 2.54 2.62 2.70 2.59 2.64 2.73 2.81 2.67 2.73 2.82 2.91
AMPS 7.2 7.3 7.6 7.9 7.8 8.0 8.2 8.5 8.4 8.7 8.9 9.3 9.0 9.3 9.6 9.9 9.6 9.9 10.2 10.6 10.2 10.5 10.8 11.2
HI PR 253 272 288 300 284 306 323 337 323 348 367 383 368 396 418 436 414 446 471 491 457 492 520 542
LO PR 110 117 128 137 117 124 135 144 121 129 141 150 127 135 148 158 133 142 155 165 138 147 160 171
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Condi tions AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves. KW=Total system power