COOLING PERFORMANCE DATA
GSX130361E*
EXPANDED PERFORMANCE DAT
A
MODEL: GSX130361E* + CAPF3636D6DB
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67715963677159636771
MBh 29.5 30.6 33.5 - 28.8 29.9 32.7 - 28.1 29.2 31.9 - 27.4 28.4 31.2 - 26.1 27.0 29.6 - 24.2 25.0 27.4 -
S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -
Delta T181612 - 191612 - 191612 - 19 16 12 - 181612 - 171511 -
1050 KW 2.37 2.42 2.48 - 2.53 2.58 2.65 - 2.67 2.72 2.80 - 2.79 2.85 2.93 - 2.90 2.96 3.04 - 2.99 3.05 3.14 -
AMPS 9.6 9.7 9.8 - 10.0 10.1 10.3 - 10.4 10.5 10.7 - 10.8 10.9 11.1 - 11.2 11.3 11.6 - 11.6 11.7 12.0 -
HI PR 176 189 200 - 197 212 224 - 224 242 255 - 256 275 291 - 288 309 327 - 318 342 361 -
LO PR 91 97 106 - 96 103 112 - 100 107 116 - 105 112 122 - 110 117 128 - 114 121 133 -
MBh 32.0 33.1 36.3 - 31.2 32.4 35.5 - 30.5 31.6 34.6 - 29.7 30.8 33.8 - 28.2 29.3 32.1 - 26.2 27.1 29.7 -
S/T 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
Delta T181612 - 181612 - 181612 - 18 16 12 - 181612 - 171511 -
70 1200 KW 2.42 2.47 2.54 - 2.59 2.64 2.71 - 2.73 2.78 2.86 - 2.86 2.91 3.00 - 2.96 3.02 3.11 - 3.06 3.12 3.21 -
AMPS 9.7 9.8 10.0 - 10.1 10.2 10.4 - 10.6 10.7 10.9 - 11.0 11.1 11.3 - 11.4 11.5 11.8 - 11.8 11.9 12.2 -
HI PR 181 195 206 - 203 219 231 - 231 249 263 - 264 284 299 - 296 319 337 - 328 353 372 -
LO PR 94 100 109 - 99 106 116 - 103 110 120 - 109 116 126 - 114 121 132 - 118 125 137 -
MBh 32.9 34.1 37.4 - 32.2 33.3 36.5 - 31.4 32.5 35.7 - 30.6 31.7 34.8 - 29.1 30.2 33.0 - 27.0 27.9 30.6 -
S/T 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.48 - 0.85 0.71 0.49 - 0.88 0.74 0.51 - 0.89 0.74 0.51 -
Delta T171511 - 181512 - 181512 - 18 15 12 - 171511 - 161411 -
1350 KW 2.44 2.49 2.55 - 2.61 2.65 2.73 - 2.75 2.80 2.88 - 2.88 2.94 3.02 - 2.99 3.05 3.14 - 3.08 3.14 3.24 -
AMPS 9.7 9.9 10.0 - 10.1 10.3 10.5 - 10.6 10.8 11.0 - 11.0 11.2 11.4 - 11.4 11.6 11.8 - 11.8 12.0 12.2 -
HI PR 183 197 208 - 205 221 234 - 234 252 266 - 266 286 302 - 299 322 340 - 331 356 376 -
LO PR 95 101 110 - 100 107 117 - 104 111 121 - 110 117 127 - 115 122 134 - 119 126 138 -
MBh 30.0 30.9 33.4 35.9 29.3 30.2 32.7 35.1 28.6 29.5 31.9 34.2 27.9
28.7
31.1 33.4 26.5 27.3 29.6 31.7 24.6 25.3 27.4 29.4
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.89
0.79
0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
Delta T21201611212016112220161122
20
16 11 21 20 16 11 20 18 15 10
1050 KW 2.39 2.43 2.50 2.57 2.55 2.60 2.67 2.75 2.69 2.74 2.82 2.90 2.81
2.87
2.95 3.04 2.92 2.98 3.07 3.16 3.01 3.07 3.16 3.26
AMPS 9.6 9.7 9.9 10.1 10.0 10.1 10.3 10.5 10.5 10.6 10.8 11.0 10.8
11.0
11.2 11.4 11.2 11.4 11.6 11.9 11.6 11.8 12.0 12.3
HI PR178191202211199215227236227244258269258
278
293306291313330344321345365380
LO PR 92 98 107 114 97 104 113 121 101 108 118 125 106
113
124132112119130138115123134143
MBh 32.5 33.5 36.2 38.9 31.8 32.7 35.4 38.0 31.0 31.9 34.5 37.1 30.2
31.1
33.7 36.2 28.7 29.6 32.0 34.4 26.6 27.4 29.7 31.8
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92
0.82
0.62 0.40 0.95 0.85 0.65 0.42 0.96 0.86 0.65 0.42
Delta T21191611211916112119161121
20
16 11 21 19 16 11 20 18 15 10
75 1200 KW 2.44 2.49 2.56 2.63 2.61 2.66 2.73 2.81 2.75 2.80 2.89 2.97 2.88
2.94
3.02 3.11 2.99 3.05 3.14 3.23 3.08 3.14 3.24 3.34
AMPS 9.7 9.9 10.0 10.2 10.1 10.3 10.5 10.7 10.6 10.8 11.0 11.2 11.0
11.2
11.4 11.6 11.4 11.6 11.8 12.1 11.8 12.0 12.2 12.5
HI PR183197208217206221234244234252266277266
287
303316300322340355331356376392
LO PR 95 101 110 118 100 107 117 124 104 111 121 129 110
117
127136115122134142119127138147
MBh 33.5 34.5 37.3 40.0 32.7 33.7 36.4 39.1 31.9 32.9 35.6 38.2 31.1
32.1
34.7 37.3 29.6 30.5 33.0 35.4 27.4 28.2 30.5 32.8
S/T 0.88 0.79 0.60 0.38 0.91 0.81 0.62 0.40 0.93 0.84 0.63 0.41 0.96
0.86
0.65 0.42 1.00 0.90 0.68 0.44 1.00 0.90 0.68 0.44
Delta T20181510201915112019151120
19
15 11 20 19 15 11 19 17 14 10
1350 KW 2.46 2.50 2.57 2.65 2.62 2.67 2.75 2.83 2.77 2.82 2.91 2.99 2.90
2.96
3.04 3.14 3.01 3.07 3.16 3.26 3.10 3.17 3.26 3.36
AMPS 9.8 9.9 10.1 10.3 10.2 10.3 10.5 10.7 10.7 10.8 11.0 11.3 11.1
11.2
11.4 11.7 11.5 11.7 11.9 12.2 11.9 12.1 12.3 12.6
HI PR185199210219208223236246236254268280269
289
306319303326344359334360380396
LO PR 96 102 112 119 101 108 118 126 105 112 123 130 111
118
129137116124135144120128139149
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves. KW=Total system power