COOLING PERFORMANCE DATA
GSX130181E*
MODEL: GSX130181E* + CAPF1824B6DB
EXPANDED PERFORMANCE DAT
A
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67715963677159636771
MBh 16.2 16.5 17.7 18.9 15.8 16.1 17.3 18.4 15.4 15.8 16.8 18.0 15.0 15.4 16.4 17.6 14.3 14.6 15.6 16.7 13.2 13.5 14.5 15.5
S/T 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.94 0.76 0.57 1.01 0.94 0.77 0.57
Delta T25242117252421172524211725 24 21172524211723221916
525 KW 1.04 1.06 1.10 1.14 1.13 1.15 1.19 1.23 1.20 1.23 1.27 1.32 1.27 1.30 1.35 1.39 1.33 1.36 1.41 1.46 1.38 1.41 1.46 1.51
AMPS 4.3 4.4 4.6 4.8 4.7 4.8 5.0 5.2 5.1 5.2 5.4 5.6 5.5 5.6 5.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8
HI PR 207 223 235 246 232 250 264 276 264 285 300 313 301 324 342 357 339 365 385 402 374 403 425 444
LO PR 105 111 121 129 110 118 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 162
MBh 17.0 17.4 18.6 19.8 16.6 17.0 18.1 19.4 16.2 16.6 17.7 18.9 15.8 16.2
17.3
18.5 15.0 15.4 16.4 17.5 13.9 14.2 15.2 16.2
S/T 0.89 0.84 0.68 0.51 0.92 0.87 0.70 0.53 0.95 0.89 0.72 0.54 0.98 0.92
0.75
0.56 1.00 0.95 0.77 0.58 1.00 0.96 0.78 0.58
Delta T23221915232320162423201624 23
20
16 23 22 19 16 21 21 18 15
80 600 KW 1.05 1.08 1.11 1.15 1.14 1.17 1.21 1.25 1.22 1.25 1.29 1.33 1.28 1.32
1.36
1.41 1.34 1.38 1.42 1.48 1.39 1.43 1.48 1.53
AMPS 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.2 5.3 5.5 5.7 5.5 5.7
5.9
6.1 5.9 6.0 6.2 6.5 6.2 6.4 6.6 6.9
HI PR 210 226 239 249 236 254 268 279 268 288 304 318 305 328
347
362 343 369 390 407 379 408 431 450
LO PR 106 113 123 131 112 119 130 138 116 124 135 144 122 130
142
151 128 136 149 158 132 141 154 164
MBh 17.5 17.
9
19.1 20.
5
17.1 17.5 18.7 20.0 16.7 17.1 18.2 19.
5
16.3 16.7 17.8 19.
0
15.
5
15.8 16.9 18.1 14.
3
14.7 15.7 16.
7
S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.80 0.60
Delta T23221915232219152322191523 22 19152222191520211814
650 KW 1.07 1.09 1.13 1.17 1.16 1.18 1.22 1.27 1.24 1.26 1.31 1.36 1.30 1.34 1.38 1.43 1.36 1.40 1.45 1.50 1.42 1.45 1.50 1.55
AMPS 4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.3 5.2 5.4 5.6 5.8 5.6 5.8 5.9 6.2 6.0 6.1 6.3 6.6 6.3 6.5 6.7 7.0
HI PR 214 230 243 253 240 258 272 284 273 293 310 323 310 334 353 368 349 376 397 414 386 415 439 457
LO PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
MBh 16.5 16.8 17.6 18.7 16.1 16.4 17.2 18.3 15.7 16.0 16.8 17.9 15.3 15.6 16.3 17.4 14.5 14.8 15.5 16.6 13.5 13.7 14.4 15.3
S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.75
Delta T27262521272625222726252227 27 25222526252124242320
525 KW 1.05 1.07 1.11 1.15 1.14 1.16 1.20 1.24 1.21 1.24 1.28 1.33 1.28 1.31 1.36 1.41 1.34 1.37 1.42 1.47 1.39 1.42 1.47 1.53
AMPS 4.4 4.5 4.6 4.8 4.7 4.9 5.0 5.2 5.2 5.3 5.5 5.7 5.5 5.6 5.8 6.1 5.9 6.0 6.2 6.4 6.2 6.4 6.6 6.8
HI PR 209 225 238 248 235 253 267 278 267 287 303 317 304 327 346 361 342 368 389 406 378 407 430 448
LO PR 106 112 123 131 112 119 130 138 116 123 135 143 122 130 141 151 128 136 148 158 132 140 153 163
MBh 17.3 17.6 18.5 19.7 16.9 17.2 18.0 19.2 16.5 16.8 17.6 18.8 16.1 16.4 17.2 18.3 15.3 15.6 16.3 17.4 14.2 14.4 15.1 16.1
S/T 0.93 0.90 0.81 0.66 0.97 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.93 0.75 1.00 1.00 0.93 0.76
Delta T25242320252523202525232025 25 23202324232022222219
85 600 KW 1.06 1.08 1.12 1.16 1.15 1.18 1.22 1.26 1.23 1.26 1.30 1.35 1.30 1.33 1.37 1.42 1.36 1.39 1.44 1.49 1.41 1.44 1.49 1.54
AMPS 4.4 4.5 4.7 4.9 4.8 4.9 5.1 5.3 5.2 5.3 5.5 5.7 5.6 5.7 5.9 6.1 5.9 6.1 6.3 6.5 6.3 6.4 6.7 6.9
HI PR 212 228 241 251 238 256 270 282 271 291 308 321 308 332 350 365 347 373 394 411 383 412 435 454
LO PR 107 114 124 132 113 120 131 140 118 125 136 145 123 131 143 153 129 138 150 160 134 142 155 166
MBh 17.8 18.2 19.0 20.3 17.4 17.8 18.6 19.8 17.0 17.3 18.2 19.4 16.6 16.9 17.7 18.9 15.8 16.1 16.8 18.0 14.6 14.9 15.6 16.6
S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.95 0.77
Delta T24242219242423202424232023 24 23202223221921212118
650 KW 1.08 1.10 1.14 1.18 1.17 1.19 1.23 1.28 1.25 1.28 1.32 1.37 1.32 1.35 1.40 1.45 1.38 1.41 1.46 1.51 1.43 1.46 1.51 1.57
AMPS 4.5 4.6 4.8 4.9 4.9 5.0 5.2 5.4 5.3 5.4 5.6 5.8 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6 6.4 6.6 6.8 7.0
HI PR 216 232 245 256 242 261 275 287 275 296 313 326 314 337 356 372 353 380 401 418 390 419 443 462
LO PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves. KW=Total system power