Technical Manual
25
COOLING PERFORMANCE DATA
GSX130611A*
EXPANDED PERFORMANCE DAT
A
COOLING OPERATION
MODEL: GSX130611/CA*F4961*6D*+EEP
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67715963677159636771
MBH 55.656.960.764.954.355.559.363.453.054.257.961.951.8 52.9 56.560.449.250.253.757.445.546.549.753.2
S/T 0.820.770.620.470.850.800.650.480.870.820.660.500.90 0.84 0.690.510.930.870.710.530.940.880.720.54
Delta T 28272319282724192827241928 27 24192827231926252217
1500 System KW 4.03 4.12 4.25 4.39 4.35 4.44 4.58 4.73 4.62 4.72 4.88 5.04 4.86 4.97 5.14 5.31 5.07 5.18 5.36 5.54 5.25 5.37 5.55 5.74
OD amps 15.7 16.1 16.6 17.2 17.0 17.4 18.0 18.7 18.5 18.9 19.6 20.3 19.8 20.3 21.0 21.8 21.1 21.6 22.4 23.2 22.4 22.9 23.7 24.7
HI PR 233 250 264 276 261 281 297 309 297 320 337 352 338 364 384 401 380 409 432 451 420 452 478 498
LO PR 100 106 116 123 105 112 122 130 110 117 127 136 115 122 134 142 121 128 140 149 125 133 145 154
MBH 57.358.662.666.956.057.261.165.354.655.859.663.853.3 54.5 58.262.250.651.755.359.146.947.951.254.7
S/T 0.860.800.650.490.890.830.680.510.910.850.700.520.94 0.88 0.720.541.000.920.750.561.000.920.750.56
Delta T 26252217262522172625221726 25 22182725221725232016
80 1750 System KW 4.07 4.15 4.28 4.42 4.38 4.48 4.62 4.77 4.66 4.76 4.92 5.08 4.90 5.01 5.18 5.35 5.11 5.23 5.40 5.59 5.29 5.41 5.59 5.79
OD amps 15.8 16.2 16.7 17.4 17.1 17.6 18.2 18.9 18.7 19.1 19.8 20.5 20.0 20.5 21.2 22.0 21.3 21.8 22.6 23.5 22.6 23.2 24.0 24.9
HI PR 235 253 267 279 264 284 300 313 300 323 341 355 342 368 388 405 384 414 437 455 425 457 482 503
LO PR 101 107 117 125 107 113 124 132 111 118 129 137 116 124 135 144 122 130 142 151 126 134 146 156
MBH 57.
6
58.
8
62.9 67.2 56.2 57.
5
61.4 65.
6
54.9 56.1 59.9 64.1 53.
6
54.
7
58.5 62.5 50.
9
52.0 55.6 59.4 47.1 48.2 51.5 55.0
S/T 0.870.820.660.500.900.850.690.510.920.870.710.530.95 0.89 0.730.541.000.930.760.561.000.940.760.57
Delta T 23221915232219162322191623 23 20162322191522211814
2000 System KW 4.10 4.19 4.32 4.46 4.42 4.51 4.66 4.81 4.70 4.80 4.96 5.12 4.94 5.06 5.22 5.40 5.16 5.27 5.45 5.63 5.34 5.46 5.64 5.84
OD amps 16.0 16.4 16.9 17.6 17.3 17.7 18.3 19.0 18.8 19.3 20.0 20.7 20.2 20.7 21.4 22.2 21.5 22.0 22.8 23.7 22.8 23.4 24.2 25.1
HI PR 237 255 270 281 266 287 303 316 303 326 344 359 345 371 392 409 388 418 441 460 429 461 487 508
LO PR 102 108 118 126 108 114 125 133 112 119 130 138 117 125 136 145 123 131 143 152 127 135 148 157
MBH 56.657.760.464.555.356.459.063.054.055.057.661.552.7 53.7 56.260.050.051.053.457.046.347.249.552.8
S/T 0.860.830.750.610.890.860.770.630.910.880.790.640.94 0.91 0.820.660.980.940.850.690.980.950.860.70
Delta T 30292824303028243030282430 30 28243029282428282623
1500 System KW 4.07 4.15 4.28 4.42 4.38 4.48 4.62 4.77 4.66 4.76 4.92 5.08 4.90 5.01 5.18 5.35 5.11 5.23 5.40 5.59 5.29 5.41 5.59 5.79
OD amps 15.8 16.2 16.7 17.4 17.1 17.6 18.2 18.9 18.7 19.1 19.8 20.5 20.0 20.5 21.2 22.0 21.3 21.8 22.6 23.5 22.6 23.2 24.0 24.9
HI PR 235 253 267 279 264 284 300 313 300 323 341 355 342 368 388 405 384 414 437 455 425 457 482 503
LO PR 101 107 117 125 107 113 124 132 111 118 129 137 116 124 135 144 122 130 142 151 126 134 146 156
MBH 58.359.462.266.456.958.160.864.955.656.759.463.354.2 55.3 57.961.851.552.555.058.747.748.751.054.4
S/T 0.900.870.780.640.930.900.810.660.960.920.830.680.99 0.95 0.860.701.000.990.890.721.001.000.900.73
Delta T 28272622282726222827262228 28 26232727262225252421
85 1750 System KW 4.10 4.19 4.32 4.46 4.42 4.51 4.66 4.81 4.70 4.80 4.96 5.12 4.95 5.06 5.22 5.40 5.16 5.27 5.45 5.63 5.34 5.46 5.64 5.84
OD amps 16.0 16.4 16.9 17.6 17.3 17.7 18.3 19.0 18.8 19.3 20.0 20.7 20.2 20.7 21.4 22.2 21.5 22.0 22.8 23.7 22.8 23.4 24.2 25.1
HI PR 237 255 270 281 266 287 303 316 303 326 344 359 345 371 392 409 388 418 441 460 429 461 487 508
LO PR 102 108 118 126 108 114 125 133 112 119 130 138 117 125 136 145 123 131 143 152 127 135 148 157
MBH 58.659.762.566.757.258.361.165.255.956.959.663.654.5 55.6 58.262.151.852.855.359.048.048.951.254.6
S/T 0.910.880.790.640.940.910.820.670.970.930.840.681.00 0.96 0.870.711.001.000.900.731.001.000.910.74
Delta T 25242320252423202524232025 25 23202424232022222119
2000 System KW 4.13 4.22 4.35 4.50 4.45 4.55 4.70 4.85 4.74 4.84 5.00 5.17 4.99 5.10 5.27 5.45 5.20 5.32 5.49 5.68 5.38 5.50 5.69 5.89
OD amps 16.1 16.5 17.1 17.7 17.5 17.9 18.5 19.2 19.0 19.5 20.1 20.9 20.4 20.9 21.6 22.4 21.7 22.2 23.0 23.9 23.0 23.6 24.4 25.4
HI PR 240 258 272 284 269 289 306 319 306 329 348 363 348 375 396 413 392 422 445 465 433 466 492 513
LO PR 103 109 119 127 109 116 126 134 113 120 131 140 119 126 138 147 124 132 144 154 129 137 149 159
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves. KW=Total system power