GPH14H Technical Manual
21
COOLING PERFORMANCE DATA
MODEL: *PH1424H41**
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 10 ± 2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9 ± 2°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Tem perature
IDB*Airflow 596367715963677159636771596367715963677159636771
MBh 23.9 24.8 27.2 - 23.4 24.2 26.5 - 22.8 23.6 25.9 - 22.2 23.1 25.3 - 21.1 21.9 24.0 - 19.6 20.3 22.2 -
S/T 0.75 0.62 0.43 - 0.77 0.65 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.86 0.72 0.50 -
Delta T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 -
955 KW 1.54 1.57 1.62 - 1.66 1.70 1.75 - 1.77 1.81 1.87 - 1.86 1.91 1.97 - 1.95 1.99 2.06 - 2.02 2.06 2.13 -
AMPS 6.4 6.5 6.7 - 6.8 7.0 7.2 - 7.4 7.6 7.8 - 7.9 8.0 8.3 - 8.3 8.5 8.8 - 8.8 9.0 9.3 -
HI PR 236 253 268 - 264 284 300 - 301 323 342 - 342 368 389 - 385 414 438 - 425 458 484 -
LO PR 111 118 129 - 117 125 136 - 122 129 141 - 128 136 148 - 134 143 156 - 139 147 161 -
MBh 23.2 24.1 26.4 - 22.7 23.5 25.7 - 22.1 22.9 25.1 - 21.6 22.4 24.5 - 20.5 21.3 23.3 - 19.0 19.7 21.6 -
S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
70 850 KW 1.52 1.56 1.61 - 1.65 1.68 1.74 - 1.75 1.79 1.85 - 1.85 1.89 1.96 - 1.93 1.97 2.04 - 2.00 2.05 2.12 -
AMPS 6.3 6.5 6.6 - 6.8 6.9 7.1 - 7.3 7.5 7.7 - 7.8 8.0 8.2 - 8.3 8.5 8.7 - 8.7 8.9 9.2 -
HI PR 233 251 265 - 262 282 297 - 298 320 338 - 339 365 385 - 381 410 433 - 421 453 479 -
LO PR 110 117 127 - 116 123 135 - 120 128 140 - 127 135 147 - 133 141 154 - 137 146 159 -
MBh 21.4 22.2 24.3 - 20.9 21.7 23.8 - 20.4 21.2 23.2 - 19.9 20.7 22.6 - 18.9 19.6 21.5 - 17.5 18.2 19.9 -
S/T 0.69 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.79 0.66 0.46 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
745 KW 1.49 1.52 1.57 - 1.60 1.64 1.69 - 1.71 1.75 1.81 - 1.80 1.84 1.90 - 1.88 1.92 1.99 - 1.95 1.99 2.06 -
AMPS 6.2 6.3 6.5 - 6.6 6.8 7.0 - 7.1 7.3 7.5 - 7.6 7.8 8.0 - 8.1 8.2 8.5 - 8.5 8.7 9.0 -
HI PR 226 243 257 - 254 273 288 - 289 311 328 - 329 354 374 - 370 398 420 - 409 440 464 -
LO PR 106 113 124 - 112 120 131 - 117 124 136 - 123 131 143 - 129 137 149 - 133 142 155 -
MBh 24.3 25.0 27.1 29.1 23.7 24.5 26.5 28.4 23.2 23.9 25.8 27.7 22.6
23.3
25.2 27.1 21.5 22.1 23.9 25.7 19.9 20.5 22.2 23.8
S/T 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.90 0.81 0.61 0.39 0.93
0.83
0.63 0.41 0.97 0.86 0.65 0.42 0.97 0.87 0.66 0.42
Delta T20181510201915102019151020
19
15 11 20 18 15 10 19 17 14 10
955 KW 1.55 1.58 1.64 1.69 1.67 1.71 1.77 1.83 1.78 1.82 1.89 1.95 1.88
1.92
1.99 2.06 1.96 2.01 2.08 2.15 2.03 2.08 2.15 2.23
AMPS 6.4 6.6 6.8 7.0 6.9 7.1 7.3 7.5 7.5 7.6 7.9 8.1 7.9
8.1
8.4 8.7 8.4 8.6 8.9 9.2 8.9 9.1 9.4 9.7
HI PR 238 256 270 282 267 287 303 316 304 327 345 360 346
372
393 410 389 419 442 461 430 463 488 509
LO PR 112 119 130 138 118 126 137 146 123 131 143 152 129
137
150 160 135 144 157 167 140 149 163 173
MBh 23.6 24.3 26.3 28.2 23.1 23.7 25.7 27.6 22.5 23.2 25.1 26.9 22.0
22.6
24.5 26.3 20.9 21.5 23.2 25.0 19.3 19.9 21.5 23.1
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.37 0.89
0.79
0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
Delta T21191611211916112119161121
19
16 11 21 19 16 11 19 18 15 10
75 850 KW 1.54 1.57 1.62 1.68 1.66 1.70 1.75 1.81 1.77 1.81 1.87 1.93 1.86
1.91
1.97 2.04 1.95 1.99 2.06 2.13 2.02 2.06 2.13 2.21
AMPS 6.4 6.5 6.7 6.9 6.8 7.0 7.2 7.5 7.4 7.6 7.8 8.1 7.9
8.0
8.3 8.6 8.3 8.5 8.8 9.1 8.8 9.0 9.3 9.6
HI PR 236 253 268 279 264 284 300 313 301 323 342 356 342
368
389 406 385 415 438 457 426 458 484 504
LO PR 111 118 129 137 117 125 136 145 122 129 141 151 128
136
149 158 134 143 156 166 139 147 161 171
MBh 21.8 22.4 24.3 26.1 21.3 21.9 23.7 25.5 20.8 21.4 23.2 24.8 20.3
20.9
22.6 24.2 19.3 19.8 21.5 23.0 17.8 18.4 19.9 21.3
S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.86
0.77
0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.80 0.61 0.39
Delta T21191611212016112120161121
20
16 11 21 19 16 11 20 18 15 10
745 KW 1.50 1.53 1.58 1.63 1.62 1.65 1.71 1.77 1.72 1.76 1.82 1.88 1.82
1.86
1.92 1.99 1.90 1.94 2.01 2.08 1.96 2.01 2.08 2.15
AMPS 6.2 6.3 6.5 6.8 6.7 6.8 7.0 7.3 7.2 7.4 7.6 7.9 7.7
7.8
8.1 8.4 8.1 8.3 8.6 8.9 8.6 8.8 9.1 9.4
HI PR 228 246 260 271 256 276 291 304 292 314 331 346 332
357
377 394 374 402 425 443 413 444 469 489
LO PR 108 114 125 133 114 121 132 141 118 126 137 146 124
132
144 153 130 138 151 161 134 143 156 166
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is A CCA (TVA) conditions
High and low pressures are measured at the liquid and suction access f ittings.
*PH1424H41**