GPH14M Spec Sheet

22 www.goodmanmfg.com SS-GPH14M
SS-GPH14M www.goodmanmfg.com 
Wiring Diagram — GPH1460M41**
2
3
SEE NOTE 2
SEE NOTE 3
EM
TR
208-230
208-230/1/60
SUPPLY VOLTAGE
C
COMP
C
S.A
S
T1
R
L1
DF1
C
H
F
RCCF
CM
HVDR
T2
C
DF2
L2
1
L
3
1
2
R W2 O
W1 Y1
G C
EM
1
C
CSR
SEE NOTE 6
THERMOSTAT
N
G
2
3
CHS
CH
Y2
C
SOL
HP
S
24V
DC
DFT
Y
C
R
RVC
LPS
CNT
R-PS1 PS2
R
W
O
R-DFT
O-RV
C-RV
DFT
2 POLE ONLY
SEE NOTE 7
SEE NOTE 4
4
5
6
PLF
SEE NOTE 2
3
CONTROL
BOX
240
2
24V
208
TR
C
1
PU
WH
BR
BL
R
O
Y2
W2
W1
C
Y1
T2
T1
L1
GND
C
L2
BK
RD
RD
BK
BK
LVJB
RCCF
RD
SA
H
C
F
PU
YL
BK
BK
RVC
BKCOMP
S
C
R
CM
BR
PU BK
YL
LPS
DFT
RD
YL
BK
YL
BL
HPS BR
PU
BL
G
YL
BL
SOLYL
BL
CSR
2
LVTB
OR
WH
WH
BL
PK
3
4
1
YL
YL
YL
YL
BK
GR
BK
PU
10
11
12
7
8
9
4
5
63
2
1
BR
GR
GR
1
23
65
4
98
7
1211
10
PU
PU
BR
BR
YL
PLM- P
GR
PU
BK
1
23
6 54
98
7
12
11
10
BR
BR
BR
YL
YL
BK
BK
PU
PU
PU
BK
PU
RD
RD
RD
BR
YL
BL
PU
BL
BL
RD
BL
BL
BL
BL
WH
WH
WH
PLF-C
PU
PU
PK
BL
BK
YL
PS2
C
C
R
C
Y
Y
R-PS1
R-DFT
DFT
0
CNT
CCR
HVDR
LVDR
W
C-RV
0-RV
0
DF2
DF1
R
DC
PU
BK
OR
RD
SEE NOTE 1
YL
SEE NOTE 7
SEE
NOTE 3
41
PLF-H
5
6
2
3
7
8
9
BL
BR
WH
GR
BK
PU
YL
BL
WH
C L G N
1
2 3
EM
4 5
GR
10
11
12
7
8
9
4
5
6
3
2
1
PLM- B
SEE NOTE 2
BL
GR YL
WH
NOTES:
1. REPLACEMENT W IRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE YELLOW AND WHITE
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3 FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPPED W HEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
USE N.E.C. CLASS 2 W IRE
6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONT ACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
FACTOR
Y WIRING
LINE VOLT AGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
208/230/1/60
THERMOSTAT
SEE NOTE 5
SEE
NOTE 4
CH
RD
CHS
GR BK PU
RD
BK
PLF-P
BK
SEE NOTE 6
BK
BL
BR
GR
OR
PU
RD
WH
YL
BLACK
BLUE
BROW N
GREEN
ORANGE
PURPLE
RED
WHITE
YELLOW
WIRE CODE
CONTACTOR
COMPRESSOR CONTACTOR RELAY
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
CONDENSER MOTOR
COMPRESSOR
COMPRESSOR SOLENOID RELAY
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH PRESSURE SWITCH
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
LOW VOLTAGE TERMINAL BLOCK
FEMALE PLUG/CONNECTOR - CONTROL
FEMALE PLUG/CONNECTOR - HEAT KIT
FEMALE PLUG/CONNECTOR - PESSURE SWITCH
MALE PLUG/CONNECTOR - BLOWER
MALE PLUG/CONNECTOR - PRESSURE SWITCH
REVERSING VALVE COIL
RUN CAPACITO R FOR COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
C
CCR
CH
CHS
CM
COMP
CSR
DC
DFT
EM
GND
HPS
HVDR
LPS
LVDR
LVJB
LVTB
PLF-C
PLF-H
PLF-P
PLM-B
PLM-P
RVC
RCCF
SA
TR
COMPONENT LEGEND
208-230/1/60 0140G03223-D
SEE NOTE 5
SEE NOTE 1
YL

     

Warning
High Voltage:           
