Specifications

24 www.goodmanmfg.com SS-GPG16M
SS-GPG16M www.goodmanmfg.com 25
Wiring Diagram — GPG1660***M41**

refer to the wiring diagram or the
unit for the most up-to-date wiring.
Warning
High Voltage:           

8
7
6
5
4
2
13
E
D
B
A
C
CONFIDENTIAL PROPERTY OF GOODMAN MANUFACTURING COMPANY, L.P. OR ITS AFFILIATES NOT TO BE DISCLOSED TO
OTHERS, COPIED, OR USED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND,
ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP
824.01 WORKMANSHIP STANDARD.
SPECIAL CHARACTERISTICS: (REFER MSP 721-01 FOR DETAILS)
=
6SIGMA = CRITICAL CHARACTERISTIC = SIGNIFICANT CHARACTERISTIC
SC
CC

LABEL, WIRING DIAGRAM
DATE: 01-23-18
ENG: SR
DWN BY: HCL-SR
DO NOT SCALE DRAWING
0140G04536
A
REV
CHK BY: DTM
SHT 1 OF 2
GOODMAN MANUFACTURING COMPANY, L.P.
TOLERANCES UNLESS
OTHERWISE NOTED
ANGLES ± 1.
.X : ± .1
.XX : ± .03
.XXX : ± .015
HOLE Ø : ± .005
TUBE CUT LG: ± .063
DRAWING TO BE INTERPRETED IN
ACCORDANCE WITH ASME Y14.100
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED
9
8
7
6
5
4
2
1
39
F
E
D
B
A
C
F
SOL
AUXILIARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
VMR
LS
4
INSTALLER/SERVICEMAN
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ON
PRESSURE SWITCH CLOSED
PRESSURE SWITCH
SWITCH
OPEN
OPEN ROLLOUT
SWITCH
IGNITION FAILURE
NORMAL OPERATION
NO POWER OR
INTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
G
R
5
7
9
Y2Y1
3
6
12
10
8
11
RS
ALS
PS
BAD SWITCH
AUX. LIMIT OPEN
ANTI-CYCLE TIMER
MAIN LIMIT OPEN
STICKING GAS VALVE
BAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCH
CHECK
CHECK
GAS PRESSURE
FLAME ROLLOUT
FLAME SENSOR
GAS VALVE
CHECK FUSE ON CONTROL
CHECK INPUT POWER
REPLACE CONTROL
GAS FLOW
CHECK
-
C
4
321
56
GV
IGN
NOTE 5
L1
F
H
C
D1
FS
TR
CM CONDENSER MOTOR
NOTE 5
C
T2 T1
T5
T3
T4
EM
FS
IIC
L2
LS
LIMIT SWITCH
VENT MOTOR RELAY
VENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)
ROLLOUT SWITCH
VMR
VM
PS
PLF
TB1
RS
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUND
FLAME SENSOR
EVAPORATOR MOTOR
RCCF
FUSEF
C
GV
FS
GND
IGN
IIC
EM
COMPRESSOR
COMP
ALS
TB1
TB1
POWER SUPPLY
240/1/60
BL
L2
C
T2
L1
T1
NOTE 2
SRC
COMP
CM
VMR
C
24V
TR
SPEED-UP
MOUN T
T1
P2
REQ UI RED
SCREW
P3
135
120
150
FUSE 3 AMP MAX
F1
LS
11
8
12
9
7
10
4
2
5
6
3
1
FS
NOTE 5
SEE
COOL
DI
L1
HEAT
UNUSED
L2
P1
ECON
ALS
PS
RS
2
1 4
5
W. R.
GAS VALVE
3 6
1 23
FS
IGN
VM
TB1
TB1
TR
TRANSFORMER
C
L2
L2
VMR
T2
SUPPLY VOLTAGE
240/1/60
L1
SEE NOTE 2
2
13
L1
C
T1
EM
L
N
H
C
RCCF
CM
VM
C
LPS
HPS
LPS
HPS
HIGH PRESSURE SWITCH
HPS
LOW PRESSURE SWITCHLPS
3. ACCESSORY ECONOMIZER PLUG ADJACENT
TO BLOWER HOUSING IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.
1. REPLACEMENT WIRE MUST BE THE SAME
SIZE AND TYPE OF INSULATION AS ORIGINAL.
(USE COPPER CONDUCTOR ONLY).
NO
TES
FACTORY WIRING
LOW VOLTAGE
EM
WIRE CODE
5. L1 AND L2 ON ICC CONTROL IS 24V INPUT.
6. SPEED TAP TERMINATIONS SHOWN ON
DIAGRAM ARE REPRESENTATIVE, BUT
ACTUAL FACTORY SETTINGS MAY BE
DIFFERENT BASED ON THE HEATING VALUE
OF THE UNIT.
Y2Y1
3
1
TO THERMOSTAT
TERMINAL BLOCK
ECON
IIC
W1
PLF
NOTE 3
RUN CAPACITOR FOR COMPRESSOR/FAN
CO
MPONENT LEGEND
GND
YL
RD
YL
WH
RD
RCCF
YL
RD
BK
BK
RD
BL
BK
BK
PU
RD
SRC
COMP
BK
PU
CM
BR
PK
240
PK
BL
TR
BL
208
OR
LS
RD
RD
W HY L
RD
RD
FS
RD
DI
L1
BL
WH
YL
YL
PU
RD
BL
BL
BL
BL
RD
GR
ALS
GR
PS
RS
PLF
YL
YL
NOTE 3
YL
YL
PU
PU
PU
BR
OR
RD
YL
WH
BR
BL
GV
TB1
PU
YL
F
F
WH
H
C
YL
LPS
HPS
YL/PK
BK
USE N.E.C. CLASS 2 WIRE.
4. USE COPPER CONDUCTORS ONLY.
HIGH VOLTAGE
OPTIONAL HIGH VOLTAGE
OPTIONAL LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
BL
NOTE 6
G
T4
EM
L
T3T2T1
C
RD
BK
N
T5
BL
YL/PK
GR
S1
S2
RC
W1
G
GR
WH
RD
BL
PU
YL
TO THERMOSTAT
W2
BR
BL
RD
BK
BK
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF
OVER CURRENT PROTECTION .
YL
PU
BR
WH
OR
RD
SEE NOTE 4
W2
3
1
2
2. FOR 208 VOLT TRANSFORMER OPERATION
MOVE BLACK WIRE FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.
7
8
9
7
89
BR
S1
S2
0140G04536-A
EQUIPMENT
GROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED
CONTROL
PLUG
CONNECTION
SMOKE/FIRE
DETECTOR
REPLACES
JUMPER WIRE
(SEE NOTE 4)
(SEE NOTE 4)
1
5
1
5
YL
WH
TB1
BR
WH
BL
YL
WH
BK
WH
SOL
BL
PU
BL
BR
YL
BR
BL
GR
RD
BL
PU
PU
PU
RD
GR
RD
BLACK
BLUE
BROWN
GREEN
ORANGE
PINK
PURPLE
RED
WHITE
YELLOW
BLUE WITH PINK STRIP
YELLOW WITH PINK STRIP
BK
BL
BR
GR
OR
PK
PU
RD
WH
YL
BL/PK
YL/PK
BL
C
R
S
COMP
C
M
H
10.75
.10
FRAME
11.25
.10
LABEL
4.50
.10
FRAME
5.00
.10
LABEL
ECN REV ZONE DESCRIPTION CHK DR DATE
1815404 A - INITIAL RELEASE HCL-SR 01-23-18
NOTE:
1. WIRING DIAGRAM LABELS MUST COMPLY WITH GOODMAN SPECIFICATION S4900149 - WIRING DIAGRAM LABEL SPECIFICATION.