Specifications
Table Of Contents
24 www.goodmanmfg.com SS-GPG16M
SS-GPG16M www.goodmanmfg.com 25
BL
YL
PU
FAULT
6
2
8
GY
YL
7
OPTIONAL HIGH VOLTAGE
RD
FS
5
COM
GR
2 FLASHES
PU
SOL
7 FLASHES
YL
LS
BK
Y2
C
EQUIPMENT GROUND
5
Y1
1
SWIT CH
87654321
W1
OT1
OT2
HUM
PJ6
PJ2
PJ4
W2
CR9
HEATER
W1 W2 C R
24 VAC
CR8
CR7
CR6
J3
CR5
C2
4
1
J2
CR2
DS1
CR1
R5
OFF
ON
DIP
E
F1 3 AMP
CR10
R3
PN. PCB00 102
(CFM)
CONFIGURATION.
DIP SWITCH
FOR PROPER
TO MANUAL
PLEASE REFER
R1
R2
E DW 2 OC O MY C O NR
HEATPUMP
CONDENSER
OUTDOOR
THERMOSTATS
HUMIDISTAT
HUMY/Y2GY1RCOT2OT1OTCOW /W2E\W1
J1
RD
PU
INDUCER
RD
GV
ECON
BR
FS
3
EM
HLO
3 FLASHES
MVL
TR
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. USE COPPER CONDUCTORS ONLY
4. FOR 208V OPERATION, REMOVE BLUE LEAD FROM INDUCER LOW
TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL ONTO
INDUCER LOW TERMINAL. PLACE BLUE LEAD ON PARK TERMINAL.
5. USE NEC CLASS 2 WIRE FOR THERMOSTAT FIELD WIRING.
6. FOR ALTERNATE CONTINUOUS FAN SPEED, CONNECT FAN TERMINAL
FROM ROOM THERMOSTAT TO GREEN WIRE FROM VSTB; SEE
INSTALLATION INSTRUCTIONS FOR DETAILS.
7. FOR DEHUMIDIFICATION, CONNECT A 24VAC DEHUMIDISTAT THAT
OPENS ON HUMIDITY RISE TO GRAY WIRE FROM THE VSTB AND TO
R ON IIC; SEE INSTALLATION INSTRUCTIONS FOR DETAILS. CUT
"HUM" JUMPER ON VSTB.
CHECK W IRI NG FOR SHORTS
HI
3
IGNITOR
FLAME SENSOR
BK
9
5
208
PU
6 FLASHES
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
LOW VOLTAGE
ODF
ON
BL BLUE
INTERGRATED IGNITION
CONTROL
P1
RS
CM
HPS
8
LIMIT SWITCH
BK
YL
-
R
C
OPEN LIMIT SWITCH
INTEGRATED IGNITION CONTROL
F
STAGE
DELAY
YL
4 FLASHES
WITHOUT INDUCER ON
HPS
GY GRAY
HLI
6
WH
LIMIT OPEN 5 TIMES IN SAME
CALL FOR HEAT
208-230/1/60
1
LS
COMPONENT LEGEND
2
GAS FLOW
C
L2
PU
CONTACTOR
H
H
3
PU
BK
PU PURPLE
VM
LOW VOLTAGE
PK PINK
LO COOL
OFF
WIRE CODE
TO
MICRO
COMP
CC
L1
F
EM
7
P2
IGN
FUSE
IIC
GND
ECON
W2
WH WHITE
L2
CC
T1
5
TR
OR ORANGE
2
BK
3
INTEGRATED IGNITION CONTROL
120
BL
ALS
LO HEAT
RD
Y2
PU
GND
1
C
PU
BR BROWN
AMBER
COMPR. SHORT CYCLE DELAY
PU
FALSE FLAME DETECTED
YL
TRANSFORMER
YL
HIGH
YL
GV
CHECK PRESSURE SWITCH
LS
PU
PS
RD
PSW/LOC OPEN
GAS PRESSURE
GAS PRESSURE
CHECK GAS VALVE
R
PRESSURE SWI TCH OPEN
L2
SEE
NOTES
6 & 7
1
CHECK JUMPER BETWEEN 1
AND 4 ON 6-CIRCUIT
CONNECTOR
HI COOL
CM
BL
CHECK AUXILIARY LIMIT SW.
R
HUM
HIGH PRESSURE SW ITCH
Y1
YL
2 FLASHES
EM
MVH
24VAC COM
5 FLASHES
RD
RCCF
SEE NOTE 2
2
2
PSW
SEE
NOTE 4
E/W1
BR
PU
T2
LO
RCCF
BR
CHECK ROLLOUT LIMIT SW.
GR
VSTB
CHECK GAS VALVE
PS
L1
BL
H
GAS FLOW
F
YL YELLOW
PU
NO POWER OR
COMPRESSOR
L2
-
S
2
SWI TCH (TEMP)
L1
PS
BK BLACK
AUXILLARY LIMIT SWITCH
ALS
G
PRESSURE SWITCH CLOSED
HIGH VOLTAGE
OFF
CHECK INPUT POWER
PU
TERMINAL
BK
L1
SEE NOTE 4
LOW
FLASHES
HI
CHECK FUSE(S)
ODF
F
NORMAL FLAME PRESENT
M
R
PU
W. R.
C
GAS
VALVE
RD
FALSE FLAME DETECTED
G
R
VARIABLE SPEED TERMINAL BOARD
GV
90
OR
PU
4
LOW
YL
VM
HI HEAT
6
IGN
VENT MOTOR
P2
BK
YL
W/W2
IGNITER
JUNCTION
TH
SEE NOTE 2
3
BK
4
F
ALS
PRESSURE SWITCH
W1
1
NORMAL OPERATION
FIELD WIRING
Y1
SEE NOTE 3
T1
WH
YL
ON
PU
OUTDOOR FAN
YL
3 MIN COMP. SHORT
CYCLE DELAY
PU
VSTB
LO COOL
CHECK
L1
GAS VALVE
6
Y1
YL
HI
SOLENOID (2ND STAGE COOL)
RD RED
OR
MVC
1
OR
BL
INTERNAL TO
INTEGRATED CONTROL
PU
INTERNAL CONTROL
POWER SUPPLY
FLAME SENSOR
-
COMP
PLUG CONNECTION
SOL
REPLACE CONTROL
CM
PU
BK
YL
4
CC
RED
EVAPORATOR MOTOR
C
SEE NOTE 3
9 FLASHES
CHECK MAIN LIMIT SWITCH
PSW
T1
8 FLASHES
RD
L1
CONDENSER MOTOR
BR
LO HEAT
150
BR
CHECK FOR SHORTS IN
FLAME SENSOR WIRING
2
BK
2
FLAME SENSOR
RS
W2
RS
208-230/1/60
C
1 FLASH
FIELD SPLICE
YL
3
5
2
GAS VALVE
FS
L2
YL
LO
1
YL
L1
BL
PARK
24V
CC
EQUIPMENT GROUND
9
W1
240
OVERCURRENT
PROT. DEVICE
1 FLASH
10 MIN
GR GREEN
YL
CC
TR
DIAGNOSTIC
LED
SWITCH (PRESS.)
F
L1
OR
T2
YL
3
HI HEAT
BR
YL
NO FLAME PRESENT
GAS VALVE
1
M
L2
CHECK VENT MOTOR
RD
YL
0140G04535-A
SUPPLY VOLTAGE
BL
NONE
5 MI N
COMP
L2
C
S
OR
CHECK MAIN LIMIT SWITCH
LINE VOLTAGE
CHECK TUBING
G
HI COOL
IDT/ODT OPEN
5
RD
FACTORY WIRING
YL
PU
VSTB
IGNITION FAILURE
CHECK REFRIGERANT
SWITCHES FOR LOSS OF
CHARGE OR HIGH HEAD
PRESSURE
LOW FLAME SIGNAL
SEE
NOTES
6 & 7
RCCF
1
BLOWER
OFF DELAY
GR
C
BK
ROLLOUT SW ITCH
CHECK PRESSURE SWITCH
BL
SEE NOTE 5
GY
PU
BK
180
INTEGRATED IGNITION CONTROL
P1
4
1
HPS
STATUS
H
C
FIELD GROUND
RD
SEE NOTE 5
BL
RD
VM
Y/Y2
BL
RUN CAPACITOR FOR COMPRESSOR/FAN
L2
SOL
BK
HLO HI LIMIT OUTPUT
HLI HI LIMIT INPUT
PSW PRESSURE SWITCH
MVL MAIN GAS VALVE LOW
MVH MAIN GAS VALVE HIGH
TH TRANSFORMER HIGH
MVC MAIN GAS VALVE COMMON
refer to the wiring diagram or the
unit for the most up-to-date wiring.
⚠ Warning
High Voltage:
⚡
Wiring Diagram — GPG1624-48***M41**