Product Specifications
GPG1624
060M41AA
GPG1630
080M41AA
GPG1636
080M41AA
GPG1642
100M41AA
GPG1648
100M41AA
Cooling Capacity
Total BTU/h 22,800 28,600 34,200 40,000 45,500
Sensible BTU/h 18,200 21,500 26,600 30,400 34,100
SEER / EER 16.0 / 12.0 15.5 / 12.0 16.0 / 12.0 16.0 / 12.0 16.0 / 12.0
Decibels 76 76 76 78 78
AHRI Reference #s 8082387 8082383 8082384 8082385 8082386
Heating Capacity (BTU/h)
High-Fire Input / Output 60,000 / 47,000 80,000 / 62,000 80,000 / 62,000 100,000 / 78,000 100,000 / 78,000
Low-Fire Input / Output 45,000 / 35,000 60,000 / 47,000 60,000 / 47,000 75,000 / 58,000 75,000 / 58,000
AFUE 81 81 81 81 81
Temperature Rise Range 35 - 65 35 - 65 35 - 65 35 - 65 35 - 65
No. of Burners 3 4 4 5 5
Orice Size (Natural/Propane) 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM 45 / 1.25MM
Evaporator Motor
Type EEM EEM EEM EEM EEM
Wheel (D x W) 10” x 8” 10” x 9” 11” x 10” 11” x 10” 11” x 10”
Indoor Nominal CFM 800 950 1,200 1,250 1,300
Motor Speed Tap (Cooling) T3 L / T4 H T3 L / T4 H T3 L / T4 H T3 L / T4 H T3 L / T4 H
RPM/Amps (Cooling) 1050 / 3.8 1050 / 3.8 1050 / 3.8 1050 / 5.4 1050 / 5.4
Horsepower 1/2 1/2 1/2 3/4 3/4
Evaporator Coil
Face Area (²) 4.3 4.3 5.7 5.7 5.7
Rows Deep/Fins per Inch 3 / 14 3 / 14 4 / 14 4 / 14 4 / 14
Piston Size (Cooling) TXV TXV TXV TXV TXV
Filter Size (²) 3.5 4.3 4.3 5.6 5.6
Drain Size (NPT) ¾” ¾” ¾” ¾” ¾”
Refrigerant Charge (oz.) 70 70 158 143 100
Condenser Fan / Coil
Horsepower - RPM 1/6 - 815 1/4 - 830 1/4 - 830 1/4 - 1,075 1/4 - 1,075
Diameter / # of Blades 22” / 3 22” / 3 22” / 3 22” / 3 22” / 3
Outdoor Nominal CFM 2,200 2,200 2,600 3,200 3,100
Face Area (²) 12.3 8.7 14.9 14.9 14.4
Rows Deep/Fins per Inch 1 / 24 2 / 27 2 / 16 2 / 16 2 / 27
Compressor
Quanty / Type / Stage 1 / Scroll / 2 1 / Scroll / 2 1 / Scroll / 2 1 / Scroll / 2 1 / Scroll / 2
Compressor RLA/LRA 11.7 / 58.3 13.1 / 73.0 15.3 / 83.0 17.9 / 96.0 21.2 / 104.0
Electrical Data
Voltage-Phase (Frequency 60Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Indoor Blower FLA/LRA 3.8 3.8 3.8 5.4 5.4
Outdoor Fan FLA/LRA 1.1 / 1.7 1.5 / 3.0 1.5 / 3.0 1.4 / 2.9 1.4 / 2.9
Total Unit Amps 16.6 18.4 20.6 24.7 28.0
Min. Circuit Ampacity ¹ 19.5 21.7 24.4 29.2 33.3
Max. Overcurrent Protecon ² 30 amps 30 amps 35 amps 45 amps 50 amps
Entrance Size Power Supply 1⅛” 1⅛” 1⅛” 1⅛” 1⅛”
Entrance Size Control Voltage ⅞” ⅞” ⅞” ⅞” ⅞”
Operating / Ship Weights (lbs) 370 / 380 397 / 407 470 / 480 495 / 505 490 / 500
¹ Wire size should be determined in accordance with Naonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.