AIRFLOW DATA APG16
CFM Rise CFM Rise CFM Rise CFM Rise
A- 505 675 540 63 720 63 A- 545 810 720 63 960 63
A 565 750 600 56 800 56 A 605 900 800 56 1065 56
A+ 620 825 660 51 880 51 A+ 665 990 880 51 1170 51
B- 540 720 610 55 810 56 B- 605 900 810 56 1075 56
B 600 800 675 50 900 50 B 670 1000 900 50 1195 50
B+ 660 880 745 45 990 45 B+ 735 1100 990 45 1315 46
C- 560 745 660 51 880 51 C- 650 970 900 50 1195 50
C 620 825 735 46 980 46 C 720 1075 1000 45 1330 45
C+ 685 910 810 42 1075 42 C+ 795 1185 1100 41 1465 41
D- 575 765 720 47 960 47 D- 665 990 990 45 1315 46
D 640 850 800 42 1065 42 D 735 1100 1100 41 1465 41
D+ 700 935 880 38 1170 38 D+ 810 1210 1210 37 1610 37
CFM Rise CFM Rise CFM Rise CFM Rise
A- 680 1015 720 63 960 63 A- 970 1170 915 61 1215 62
A 755 1125 800 56 1065 56 A 1080 1300 1015 55 1350 56
A+ 830 1240 880 51 1170 51 A+ 1185 1430 1115 50 1485 51
B- 725 1080 810 56 1075 56 B- 1045 1260 1015 55 1350 56
B 805 1200 900 50 1195 50 B 1160 1400 1125 50 1495 50
B+ 885 1320 990 45 1315 46 B+ 1280 1540 1240 45 1650 45
C- 755 1125 900 50 1195 50 C- 1085 1305 1125 50 1495 50
C 840 1250 1000 45 1330 45 C 1205 1450 1250 45 1665 45
C+ 920 1375 1100 41 1465 41 C+ 1325 1595 1375 41 1830 41
D- 800 1195 990 45 1315 46 D- 1120 1350 1240 45 1650 45
D 890 1325 1100 41 1465 41 D 1245 1500 1375 41 1830 41
D+ 980 1460 1210 37 1610 37 D+ 1370 1650 1515 37 2015 37
CFM Rise CFM Rise
A- 1150 1305 900 63 1195 63
A 1275 1450 1000 56 1330 56
A+ 1405 1595 1100 51 1465 51
B- 1190 1350 1015 55 1350 56
B 1320 1500 1125 50 1495 50
B+ 1450 1650 1240 45 1650 45
C- 1230 1395 1125 50 1495 50
C 1365 1550 1250 45 1665 45
C+ 1500 1705 1375 41 1830 41
D- 1265 1440 1240 45 1650 45
D 1410 1600 1375 41 1830 41
D+ 1550 1760 1515 37 2015 37
APG1648100M41** - Rise Range: 35° 65°
Tap Low Cool High Cool
Low Heat High Heat
APG1636080M41** - Rise Range: 35° - 65° APG1642100M41** - Rise Range: 35° - 65°
Tap Low Cool High Cool
Low Heat High Heat
Tap Low Cool High Cool
Low Heat High Heat
APG1624060M41** - Rise Range: 35° - 65° APG1630080M41** - Rise Range: 35° - 65°
Tap Low Cool High Cool
Low Heat High Heat
Tap Low Cool High Cool
Low Heat High Heat
X = Outside of Temperature Rise Range - Not Recommended.
NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation,
external static pressure should not exceed 0.8" w.c.