Service Manual

PRODUCT IDENTIFICATION
8
MODEL # MFG # DESCRIPTION
DCVK-20
(CVENT-2)
DCVK-30
(CVENT-3)
N/A
Concentric Vent Kit
. For use with Amana® Brand Modulating furnace models. This kit is designed to allow
terminations of a direct vent furnace to be "concentrically" vented through a wall or roof. This kit allows a single
penetration to support terminations for both the vent/flue and the combustion air intake pipe. The DCVK-20 (2")
and DCVK-30 (3") kits are certified for models listed above. See specification sheets on future models for use
of the vent kit.
DEHUM1
P1227801F
Dehumidistat.
For use with Goodman® & Amana® Brand two-stage variable speed modulating furnace
models. Wall mounted, 24 volt humidity control available as a Dehumidistat used to reduce the airflow in the air
conditioning mode when necessary to lower the humidity in an occupied home to prevent dew build-up
associated with high humidity levels. This control features a moisture-sensitive nylon element and also
provides positive ON-OFF settings for manual operation. The control is a normally closed switch that opens on
humidity rise causing the blower to switch to a lower speed to control the humidity within the structure.
EFR02
N/A
External Filter Rack Kit
. For use with Goodman
®
and Amana
®
Brand 97% upflow, variable speed *MVM 34.5"
modulating gas furnaces. This kit is intended to provide a location, external to the furnace casing for installation
of a permanent filter. The rack is mounted over the indoor air blower compartment area of either side panel,
and provide filter retention as well as a location for attaching return air ductwork.
0170K00000S
N/A
Side Wall Only Concentric Vent Kit
. For use with 96% modulating furnace models. This kit is to be used with
2" - 3" vent systems. The vent kit must terminate outside the structure. This kit is NOT intended for use with
single pipe (indirect vent) installations.
0170K00001S
N/A
Side Wall Only Concentric Vent Kit
. For use with 96% modulating furnace models. This kit is to be used with
2" vent systems. The vent kit must terminate outside the structure. This kit is NOT intended for use with single
pipe (indirect vent) installation
LPLP03
N/A
LP Gas Low Pressure Kit
. Designed for application on Goodman® and Amana® Brand's 80% and 90% single-
stage, two-stage and modulating furnaces converted to LP gas. The kit monitors gas line pressure with a
pressure switch and will open the circuit to the gas valve if the LP tank pressure gets low.
LPM-09
N/A
LP Conversion Kit
Converts a 34.5" modulating furnace to operate on L.P. gas. The kit contains an L.P. gas
valve and a set of six L.P. orifices.
RF000142
N/A
Drain Coupling Kit
For use when the drain/vent elbow has been removed in a horizontal left installation. This
kit prevents condensate from getting in the inducer and routes the condensate to a drain.
MFG. # DESCRIPTION
PCBKF201
1st Revision to
Modulating Control
Board
Software revision to allow ECM motor to store shared data
PCBKF202
2nd Revision to
Modulating Control
Board
Software revision for operation with Daikin Inverter