Service Manual
PRODUCT IDENTIFICATION
6
MODEL: AMVM97 REV AA
Equipment Type Amana Brand Residential Gas Furnace
Heating Stages Modulating (35% - 100% of rated input)
Cooling Stages Two
Control Type ClimateTalk
™ or Conventional 24 Volt
Blower Motor Type 4 Wire Variable Speed ECM
AMVM97
0603BN 0803BN 0804CN 1005CN 1205DN
Installation Positions
UF, Hor L/R UF, Hor L/R UF, Hor L/R UF, Hor L/R UF, Hor L/R
BTUH Input Range (X 1000)
21 - 60 28 - 80 28 -80 35 - 100 42 - 120
A/C Capable Tons
1.5 - 3 1.5 - 3 2 - 4 2 - 5 2 - 5
Cabinet Hight "
34.5 34.5 34.5 34.5 34.5
Cabinet Width "
17.5 17.5 21 21 24.5
Heating CFM @ 100% Firing Rate
1059 1316 1337 1870 1940
ECM Motor H.P.
Draft Inducer
Gas Valve
24 VAC Heating Inputs
24 VAC Cooling Inputs
Primary Heat Exchanger
Accessory Terminals
Gas Line Entry
Revision Attributes First revision of 34.5" modulating up flow furnace
Left or Right
3
Ø Variable Speed
24 VAC, Modulates by Pneumatic signal
W1 / W2
Y1 / Y2
Stainless Steel
EAC terminal, HUM IN / HUM OUT terminals
MODEL: GMVM97 REV AA
Equipment Type Goodman Brand Residential Gas Furnace
Heating Stages Modulating (35% - 100% of rated input)
Cooling Stages Two
Control Type ClimateTalk
™ or Conventional 24 Volt
Blower Motor Type 4 Wire Variable Speed ECM
GM V M9 7
0603BN 0803BN 0804CN 1005CN 1205DN
Installation Positions
UF, Hor L/R UF, Hor L/R UF, Hor L/R UF, Hor L/R UF, Hor L/R
BTUH Input Range (X 1000)
21 - 60 28 - 80 28 -80 35 - 100 42 - 120
A/C Capable Tons
1.5 - 3 1.5 - 3 2 - 4 2 - 5 2 - 5
Cabinet Hight "
34.5 34.5 34.5 34.5 34.5
Cabinet Width "
17.5 17.5 21 21 24.5
Heating CFM @ 100% Firing Rate
1059 1316 1337 1870 1940
ECM Motor H.P.
Draft Inducer
Gas Valve
24 VAC Heating Inputs
24 VAC Cooling Inputs
Primary Heat Exchanger
Accessory Terminals
Gas Line Entry
Revision Attributes First revision of 34.5" modulating up flow furnace
3
Ø Variable Speed
Left or Right
EAC terminal, HUM IN / HUM OUT terminals
24 VAC, Modulates by Pneumatic signal
W1 / W2
Y1 / Y2
Aluminized Steel
MODEL: GCVM97
REV AA
Equipment Type Goodman Brand Residential Gas Furnace
Heating Stages Modulating (35% - 100% of rated input)
Cooling Stages Two
Control Type ClimateTalk
™ or Conventional 24 Volt
Blower Motor Type 4 Wire Variable Speed ECM
GCV M97
0603BN 0803BN 0804CN 1005CN
Installation Positions
CF, Hor L/R CF, Hor L/R CF, Hor L/R CF, Hor L/R
BTUH Input Range (X 1000)
21 - 60 28 - 80 28 -80 35 - 100
A/C Capable Tons
1.5 - 3 1.5 - 3 2 - 4 2 - 5
Cabinet Hight "
34.5 34.5 34.5 34.5
Cabinet Width "
17.5 17.5 21 21
Heating CFM @ 100% Firing Rate
950 1146 1325 1779
ECM Motor H.P.
Draft Inducer
Gas Valve
24 VAC Heating Inputs
24 VAC Cooling Inputs
Primary Heat Exchanger
Accessory Terminals
Gas Line Entry
Revision Attributes First revision of 34.5" modulating counter flow furnace
Left or Right
3
Ø Variable Speed
24 VAC, Modulates by Pneumatic signal
W1 / W2
Y1 / Y2
Aluminized Steel
EAC terminal, HUM IN / HUM OUT terminals
MODEL: ACVM97
REV AA
Equipment Type Amana Brand Residential Gas Furnace
Heating Stages Modulating (35% - 100% of rated input)
Cooling Stages Two
Control Type ClimateTalk
™ or Conventional 24 Vol
t
Blower Motor Type 4 Wire Variable Speed ECM
ACVM97
0603BN 0803BN 0804CN 1005CN
Installation Positions
CF, Hor L/RCF, Hor L/RCF, Hor L/RCF, Hor L/R
BTUH Input Range (X 1000)
21 - 60 28 - 80 28 -80 35 - 100
A/C Capable Tons
1.5 - 3 1.5 - 3 2 - 4 2 - 5
Cabinet Hight "
34.5 34.5 34.5 34.5
Cabinet Width "
17.5 17.5 21 21
Heating CFM @ 100% Firing Rate
950 1146 1325 1779
ECM Motor H.P.
Draft Inducer
Gas Valve
24 VAC Heating Inputs
24 VAC Cooling Inputs
Primary Heat Exchanger
Accessory Terminals
Gas Line Entry
Revision Attributes First revision of 34.5" modulating counter flow furnace
Left or Right
3
Ø Variable Speed
24 VAC, Modulates by Pneumatic signal
W1 / W2
Y1 / Y2
Stainless Steel
EAC terminal, HUM IN / HUM OUT terminals