GMSS92 Technical Manual

FURNACE SPECIFICATIONS
6
*MSS92
*MSS92
0402BNA
*MSS92
0603BNA
*MSS92
0803BNA
*MSS92
0804CNA
*MSS92
0805CNA
*MSS92
1004CNA
*MSS92
1005CNA
*MSS92
1205DNA
Heating Data
High Fire Inpu
40,000 60,000 80,000 80,000 80,000 100,000 100,000 120,000
High Fire Outpu
36,840 55,260 73,680 73,680 73,680 92,100 92,100 110,520
AFUE²
92 92 92 92 92 92 92 92
Temperature Rise Range (°F)
30 - 60 35 - 65 35 - 65 35 - 65 25 - 55 35 - 65 35 - 65 35 - 65
Vent Diameter³
2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 3"
No. of Burners 23444556
Circulator Blower
Available AC @ 0.5" ESP
1.5 - 3 1.5 - 3 1.5 - 3 3 - 5 3 - 5 3 - 5 3 - 5 3 - 5
Size (D x W) 10" x 8" 10" x 8" 10" x 8" 10" x 10" 11" x 10" 10" x 10" 11" x 10" 11" x 11"
Horsepower @ 1075 RPM
1/3 1/3 1/3 1/2 3/4 1/2 3/4 3/4
Speed 44444444
Filter Size (in²)
Permanent
363 491 654 654 818 818 818 981
Disposable 182 245 327 327 409 409 409 491
Electrical Data
Min. Circuit Ampacity
9.6 9.6 9.6 11.7 13.7 11.7 13.7 13.7
Max. Overcurrent Device (am ps )
15 15 15 15 15 15 15 15
Shipping Weight (lbs)
109 112 115 137 138 139 140 152
¹ Natural Gas BTU/h
² DOE AFUE based upon Isolated Combustion System (ICS)
Note s
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½" FPT
For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
³ Installer must supply one or tw o PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either
2" or 3" in diameter, depending upon furnace input, number of elbow s, length of run and installation (1 or 2 pipes). The optional Combustion
Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC.
?
Minimum Circuit Ampacity = (1.25 x Circulator Blow er Amps) + ID Blow er amps. Wire size should be determined in accordance w ith
National Electrical Codes. Extensive w ire runs w ill require larger w ire sizes.
?
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit
breakers of the same size as noted.
For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances
than the minimum clearances listed above. In all cases, accessibility clearance must take precedencee over clearances from the enclosure
w here accessibility clearances are greater.
Important: Size fuses and w ires properly and make electrical connection in accordance w ith the National Electrical Code and/or all existing
local codes.