GMS8 Installation Manual
5
B10259-216
CO can cause serious illness including permanent brain
damage or death.
Advertencia especial para la inst alación de calentadores ó manejadoras
de aire en áreas cerradas com o estacionam ientos ó cuartos de servicio .
B10259-216
El monóxido de carbono puede causa r e nfermeda des severas
como daño cerebral permanente ó muert e.
Las emisiones de monóxido de carbono pueden circular a t ravés
del aparat o cuando se opera en cualq uier m odo.
B10259-216
RISQUE D'EM POISONNEM ENT AU
M ONOXYDE DE CARBONE
Le monoxyde de
des
carbone peut causer des maladies graves telles que
domm ages permanents au cerveau et meme la m ort.
Cette ventilation est nécessaire pour éviter le danger d'intoxication
au CO pouvant survenir si un appare il produisant du monoxyde
de carbone co ntinue de fonct ionner au sein de la zone confinée.
S
HOULD
OVERHEATING
OCCUR
OR
THE
GAS
SUPPLY
FAIL
TO
SHUT
OFF
,
TURN
OFF
THE
M ANUAL
GAS
SHUTOFF
VALVE
EXTERNAL
TO
THE
FURNACE
BEFORE
TURNING
OFF
THE
ELECTRICAL
SUPPLY
.
WARNING
P
OSSIBLE
PROPERTY
DAM AGE
,
PERSONAL
INJURY
OR
DEATH
DUE
TO
FIRE
,
EXPLOSION
,
SM OKE
,
SOOT
,
CONDENSATION
,
ELECTRICAL
SHOCK
OR
CARBON
M ONOXIDE
M AY
RESULT
FROM
IM PROPER
INSTALLATION
,
REPAIR
OPERATION
,
OR
M AINTENANCE
OF
THIS
PRODUCT
.
WARNING
T
O
PREVENT
PERSONAL
INJURY
OR
DEATH
DUE
TO
IM PROPER
INSTALLATION
,
ADJUSTM ENT
,
ALTERATION
,
SERVICE
OR
M AINTENANCE
,
REFER
TO
THIS
M ANUAL
. F
OR
ADDITIONAL
ASSISTANCE
OR
INFORM ATION
,
CONSULT
A
QUALIFIED
INSTALLER
,
SERVICER
AGENCY
OR
THE
GAS
SUPPLIER
.
WARNING
T
O
PREVENT
PERSONAL
INJURY
OR
DEATH
DUE
TO
ASPHYXIATION
,
THIS
FURNACE
M UST
BE
C
ATEGORY
I
VENTED
. D
O
NOT
VENT
USING
C
ATEGORY
III
VENTING
.
P
ROVISIONS
M UST
BE
M ADE
FOR
VENTING
COM BUSTION
PRODUCTS
OUTDOORS
THROUGH
A
PROPER
VENTING
SYSTEM
. T
HE
LENGTH
OF
FLUE
PIPE
COULD
BE
A
LIM ITING
FACTOR
IN
LOCATING
THE
FURNACE
.
WARNING
ADDITIONAL SAFETY CONSIDERATIONS
• This furnace is approved for Category I Venting only.
• Provisions must be made for venting combustion
products outdoors through a proper venting system. The
length of flue pipe could be a limiting factor in locating
the furnace.
SHIPPING I NSPECTION
All units are securely packed in shipping containers tested ac-
cording to International Safe Transit Association specifications.
The carton must be checked upon arrival for external damage. If
damage is found, a request for inspection by carrier ’s agent must
be made in writing immediately.
The furnace must be carefully inspected on arrival for damage
and bolts or screws which may have come loose in transit. In the
event of damage the consignee should:
1. M ake a notation on delivery receipt of any visible damage
to shipment or container.
2. Notify carrier promptly and request an inspection.
3. W ith concealed damage, carrier must be notified as soon
as possible - preferably within five days.
4. File the claim with the following support documents within
a nine month statute of limitations.
• Original or certified copy of the Bill of Lading, or
indemnity bond.
• Original paid freight bill or indemnity in lieu thereof.
• Original or certified copy of the invoice, showing trade
and other discounts or reductions.
• Copy of the inspection report issued by carrier’s
representative at the time damage is reported to carrier.
The carrier is responsible for making prompt inspection of dam-
age and for a thorough investigation of each claim. The distribu-
tor or manufacturer will not accept claims from dealers for trans-
portation damage.
Keep this literature in a safe place for future reference.