GMEC96 Service Manual

SYSTEM OPERATION
34
DIP SWITCH S ETTINGS
HEATING
DIP SWITCH SETTING
Switch Bank 3
Static
0. 6 0. 7 0. 8
Switch 1 2 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM
W1
1796 41 1753 42 1697 44 1645 45 1589 47 1536 1478 1425
W2
2211 48 2162 49 2122 50 2076 51 2029 52 1986 1984 1942
W1
1106
67
1017
73
946
N/ A
855
N/ A
764
N/ A
681 605 N/ A
W2
2211 48 2162 49 2122 50 2076 51 2029 52 1986 1984 1942
W1
1106
67
1017
73
946
N/ A
855
N/ A
764
N/ A
681 605 N/ A
W2
1399 75 1327 N/ A 1259 N/ A 1185 N/ A 1118 N/ A 1051 980 913
W1
1399 53 1327 56 1259 59 1185 62 1118 66 1051 980 913
W2
1683
63
1628
65
1565
67
1511
70
1445
73
1387 1340 1276
*NOT RECOMMENDED
**Factory Default
0. 3 0. 4 0. 5
ON ON*
OFF ON
0. 1 0. 2
**OFF OFF
ON OFF
COOLING
DIP SWITCH SETTING 0.10.20.30.40.50.60.70.8
Switch Bank 2 CFM CFM CFM CFM CFM CFM CFM CFM
Switch 1 2 3
G
1796 1753 1697 1645 1589 1536 1478 1425
Ylo
1106 1017 946 855 764 681 605 N/A
Y
1683 1628 1565 1511 1445 1387 1340 1276
Ylo
1106 1017 946 855 764 681 605 N/A
Y
1399 1327 1259 1185 1118 1051 980 913
Ylo
1399 1327 1259 1185 1118 1051 980 913
Y
1683 1628 1565 1511 1445 1387 1340 1276
Ylo
1399 1327 1259 1185 1118 1051 980 913
Y
1796 1753 1697 1645 1589 1536 1478 1425
Ylo
1399 1327 1259 1185 1118 1051 980 913
Y
2211 2162 2122 2076 2029 1986 1984 1942
Ylo
1106 1017 946 855 764 681 605 N/A
Y
1683 1628 1565 1511 1445 1387 1340 1276
*MEC961205DN
**OFF OFF OFF
ON OFF OFF
ON ON OFF
OFF ON OFF
OFF OFF ON
OFF ON ON