GMEC96 Service Manual

SYSTEM OPERATION
31
DIP SWITCH S ETTINGS
HEATING
DIP SWITCH SETTING
Switch Bank 3
Static
0. 6 0. 7 0.8
Switch 1 2 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM
W1
1281 38 1220 40 1152 43 1096 45 1031 48 978 914 856
W2
1839 38 1790 39 1757 40 1699 41 1665 42 1615 1568 1527
W1
1408 35 1337 37 1279 39 1218 40 1167 42 1112 1062 999
W2
1839 38 1790 39 1757 40 1699 41 1665 42 1615 1568 1527
W1
1408 35 1337 37 1279 39 1218 40 1167 42 1112 1062 999
W2
1185 N/ A 1121 N/ A 1058 N/ A 992 N/ A 933 N/ A 868 808 750
W1
1185 42 1121 44 1058 47 992 50 933 53 868 808 519
W2
1727 41 1691 42 1642 43 1600 44 1545 46 1504 1449 1410
*NOT RECOMMENDED
**Fact ory Def ault
OFF ON
0. 1 0. 4 0. 5
** OFF OFF
ON OFF
ON ON*
0. 2 0.3
COOLING
DIP SWITCH SETTING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Sw itch Bank 2 CFM CFM CFM CFM CFM CFM CFM CFM
Switch 1 2 3
G
1281 1220 1152 1096 1031 978 914 856
Ylo
1408 1337 1279 1218 1167 1112 1062
999
Y
1727 1691 1642 1600 1545 1504 1449 1410
Ylo
1185 1121 1058 992 933 868 808 750
Y
1727 1691 1642 1600 1545 1504 1449 1410
Ylo
1185 1121 1058 992 933 868 808 750
Y
1281 1220 1152 1096 1031 978 914 856
Ylo
1185 1121 1058 992 933 868 808 750
Y
1839 1790 1757 1699 1665 1615 1568 1527
Ylo
1408 1337 1279 1218 1167 1112 1062
999
Y
1727 1691 1642 1600 1545 1504 1449 1410
OFF ON ON
*MEC960804CN
OFF OFF ON
**OFF OFF OFF
ON ON OFF
OFF ON OFF