GMEC96 Service Manual
SYSTEM OPERATION
29
DIP SWITCH S ETTINGS
HEATING
DIP SWITCH SETTING
Switch Bank 3
Static
0. 6 0. 7 0. 8
Switch 1 2 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM
W1
894 41 846 44 780 47 720 51 660 56 603 554 505
W2
1328 40 1287 41 1249 42 1215 43 1170 45 1131 1085 1046
W1
782 47 629 59 547 N/ A 469 N/ A 396 N/ A N/ A N/ A N/ A
W2
1328 40 1287 41 1249 42 1215 43 1170 45 1131 1085 1046
W1
782 47 629 59 547 N/ A 469 N/ A 396 N/ A N/ A N/ A N/ A
W2
1149 46 1104 48 1057 50 1017 52 963 55 918 865 822
W1
1149 32 1104 33 1057 35 1017 36 963 38 918 865 822
W2
1236 43 1189 44 1149 46 1101 48 1066 50 1017 969 928
**Factory Default
**OFF OFF
ON OFF
ON ON
OFF ON
0. 1 0. 2 0. 3 0. 4 0. 5
COOLING
DIP SWITCH SETTING
Static
0.10.20.30.40.50.60.70.8
Switch Bank 2 CFM CFM CFM CFM CFM CFM CFM CFM
Switch 1 2 3
G
894 846 780 720 660 603 554 505
Ylo
782 629 547 469 396 333
N/A N/A
Y
1236 1189 1149 1101 1066 1017 969 928
Ylo
782 629 547 469 396 333
N/A N/A
Y
1149 1104 1057 1017 963 918 865 822
Ylo
1149 1104 1057 1017 963 918 865 822
Y
1236 1189 1149 1101 1066 1017 969 928
Ylo
1149 1104 1057 1017 963 918 865 822
Y
1328 1287 1249 1215 1170 1131 1085 1046
Ylo
782 629 547 469 396 333
N/A N/A
Y
1236 1189 1149 1101 1066 1017 969 928
**OFF OFF OFF
ON OFF OFF
ON ON OFF
OFF ON ON
*MEC960603BN
OFF OFF ON