GMEC96 Service Manual
SYSTEM OPERATION
28
DIP SWITCH S ETTINGS
HEATING
DIP SWITCH SETTING
Switch Bank 3
Static
0. 6 0. 7 0. 8
Switch 1 2 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM
W1
847 29 694 36 611 41 535 47 471 53 415 357 313
W2
989 36 932 38 882 40 819 43 773 46 695 650 586
W1
856 29 667 37 546 46 466 53 413 N/ A 357 302 N/ A
W2
989 36 932 38 882 40 819 43 773 46 695 650 586
W1
856 29 667 37 546 46 466 53 413 N/ A 357 302 N/ A
W2
960 37 898 40 840 42 780 46 711 50 659 596 547
W1
960 26 898 28 840 30 780 32 711 35 659 596 547
W2
1143 31 1095 32 1046 34 996 36 946 38 890 834 778
**Factory Default
**OFF OFF
ON OFF
ON ON
OFF ON
0. 1 0. 2 0. 3 0. 4 0. 5
COOLING
DIP SWITCH SETTING
Static
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Switch Bank 2 CFM CFM CFM CFM CFM CFM CFM CFM
Switch 1 2 3
G
847 694 611 535 471 415 357 313
Ylo
856 667 546 466 413 357 302
N/A
Y
1143 1095 1046 996 946 890 834 778
Ylo
856 667 546 466 413 357 302
N/A
Y
960 898 840 780 711 659 596 547
Ylo
960 898 840 780 711 659 596 547
Y
1143 1095 1046 996 946 890 834 778
Ylo
960 898 840 780 711 659 596 547
Y
989 932 882 819 773 695 650 586
Ylo
856 667 546 466 413 357 302
N/A
Y
1143 1095 1046 996 946 890 834 778
Ylo
989 932 882 819 773 695 650 586
Y
1143 1095 1046 996 946 890 834 778
*MEC960402BN
**OFF OFF OFF
ON OFF OFF
ON ON OFF
OFF OFF ON
OFF ON ON
ON OFF ON