Submittal Sheet
12 .com
.com 13
GM9S96 Low Stage Cooling Airflow Data
CFM & Temperature Rise vs. External Static Pressure
Model
THERMOSTAT
CALL
TAP #
External Static Pressure, (Inches Water Column)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM CFM CFM CFM CFM CFM CFM CFM
*M9S96
0403A*
F01 705 509
F02 1079 1055 1027 935
F03 915 881 780 737
887 855 823 790 751 705
F05 1135 1078 1021 933
1189 1138 1111 1085 1059 1032 1001
F07 1218 1197 1172 1123 1099
F08 1313 1288 1239 1215 1189
F09 1305 1280 1239 1193
*M9S96
0603B*
F01 758 572 512
F02 1218 1178 1100 977 937
F03 1123 1003 920 871
1121 1083 953 818
F05 902 851 801 585
917 812 708
F07 1273 1207 1171 1128 1089 1051 1012
F08 1335 1301 1228 1192 1118 1078
F09 1390 1327 1297 1193
*M9S96
0803B*
F01 715 589 279
F02 1385 1355 1322 1291 1255 1219
F03 1388 1325 1291 1259 1223 1191 1157
1290 1252 1215 1182 1107 1071 1032
F05 817 710
985 892 797
F07 1118 1078 1037 992 952 910 822
F08 1191 1153 993 951 911
F09 1377 1283
*M9S96
0804C*
F01 1019 952 878
F02 1791 1700 1583 1538
F03 1559 1512 1370 1325 1271
1537 1301 1190
F05 1289 1180 1122 1058 991 917
1375 1329 1283 1227 1108
F07 1703 1585 1537
F08
1919 1890 1807 1771 1735
F09 1952 1921 1885 1731
Notes
•