GM9C96 Installation Manual






 

 


 



 

       


      
     

Clearance in accordance with local installation codes, the
requirements of the gas supplier and the manufacturer's
installation instructions.
Dégaugement conforme aux codes d'installation locaux, aux
exigences du fournisseur de gaz et aux instructions
d'installation du fabricant.



-




Vent/Flue Pipe
and Combustion Air Pipe



POSITION* SIDES REAR FRONT BOTTOM FLUE TOP
Upflow 0" 0" 3" C 0" 1"
Horizontal 6" 0" 3" C 0" 6"
*M9C96 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
(INCHES)
C = If placed on combustible floor, floor MUST be wood only.
POSITION* SIDES REAR FRONT BOTTOM FLUE TOP
Counterflow 0" 0" 3" C 0" 1"
Horizontal 6" 0" 3" C 0" 6"
*C9C96 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
(INCHES)
C = If placed on combustible floor, floor MUST be wood only.
NC = For installation on non-combustible floors only. A combustible
subbase must be used for installations on combustible flooring.
TOP
BOTTOM
TOP
BOTTOM


-






-
