GDS8 Technical Manual

7
PRODUCT DESIGN
GHS8***B*
Part Number 0130M00063 20162903
Open Setting F) 140 160
GHS80403A*B*
--- 1
GHS80604B*B* 1---
GHS80805C*B*
1---
PRIMARY LIMIT
Part Number 0130F00038
Open Setting (°F)
120
GHS80403A***
1
GHS80604B***
1
GHS80805C***
1
AUXILIARY LIMIT SWITCHES
Part Number 10123529
Open Setting (°F) 300
GHS80403A*** 2
GHS80604B*** 2
GHS80805C*** 2
ROLLOUT LIMIT SWITCHES
For installations in Canada, the GHS furances are certified only to 4,500 ft.
* Negative pressure readings are in inches of water column (*w.c.)
Model
Trip Point
ID Blower
Pressure
Switch
ID Blower
Pressure
Switch
Part #
GHS80403A*B* -0.70 B1370158
GHS80604B*B* -0.80 0130F00042
GHS80805C*B*
-0.75 B1370179
PRESSURE SWITCH TRIP POINTS
AND USAGE CHART