GCVM96 & GMVM96 Technical Information

10
PRODUCT DESIGN
TRIP POINT
COIL COVER
PRESSURE
SWITCH
COIL COVER
PRESSURE
SWITCH
PART #
TRIP POINT
ID BLOWER
PRESSURE
SWITCH
ID BLOWER
PRESSURE
SWITCH
PART #
A/GMVM960603BX
-0.96 -0.81 -0.25 -0.10 -0.10 20197308 -0.81 0130F00155
A/GMVM960805CX
-0.96 -0.81 -0.25 -0.10 -0.10 20197308 -0.81 0130F00155
A/GMVM961005DX
-0.85 -0.70 -0.25 -0.10 -0.10 20197308 -0.70 0130F00154
A/GMVM961155DX
-1.01 -0.86 -0.25 -0.10 -0.10 20197308 -0.86 0130F00156
A/GCVM960604CX
-1.01 -0.86 -0.25 -0.10 -0.10 0130F00070 -0.86 0130F00156
A/GCVM960805DX
-0.96 -0.81 -0.25 -0.10 -0.10 0130F00070 -0.81 0130F00155
GCVM961005DX
-0.85 -0.70 -0.25 -0.10 -0.10 0130F00070 -0.70 0130F00154
PRESSURE SWITCH TRIP POINTS AND USAGE CHART
(1) Data given is least negative pressure required for pressure switch to close.
MODEL
NEGATIVE
PRESSURE
ID BLOWER
WITH FLUE
NOT FIRING
TYPICAL
SEA
LEVEL
DATA
(1)
PRESSURE SWITCH TRIP POINTS AND USAGENEGATIVE
PRESSURE
ID BLOWER
WITH FLUE
FIRING
TYPICAL
SEA
LEVE
DATA
(2 )
NEGATIVE
PRESSURE
COIL COVER
WITH FLUE
FIRING
TYPICAL
SEA
LEVE
DATA
(2)
NEGATIVE
PRESSURE
COIL COVER
WITH FLUE
NOT FIRING
TYPICAL
SEA
LEVEL
DATA
(1)
(2) Data given is the least negative pressure required for pressure switch to remain closed.