GCVM96 & GMVM96 Installation Instructions

45
DIP S
WITCHES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
A OFF OFF --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
B ON OFF --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
C OFF ON --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
D
ON ON
--- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
A --- --- OFF OFF --- --- --- --- --- --- --- --- --- --- --- --- --- ---
B --- ---
ON OFF
--- --- --- --- --- --- --- --- --- --- --- --- --- ---
C --- --- OFF ON --- --- --- --- --- --- --- --- --- --- --- --- --- ---
D --- --- ON ON --- --- --- --- --- --- --- --- --- --- --- --- --- ---
A --- --- --- --- OFF OFF --- --- --- --- --- --- --- --- --- --- --- ---
B --- --- --- ---
ON OFF
--- --- --- --- --- --- --- --- --- --- --- ---
C --- --- --- --- OFF ON --- --- --- --- --- --- --- --- --- --- --- ---
D --- --- --- --- ON ON --- --- --- --- --- --- --- --- --- --- --- ---
A --- --- --- --- --- ---
OFF OFF
--- --- --- --- --- --- --- --- --- ---
B --- --- --- --- --- --- ON OFF --- --- --- --- --- --- --- --- --- ---
C --- --- --- --- --- --- OFF ON --- --- --- --- --- --- --- --- --- ---
D --- --- --- --- --- --- ON ON --- --- --- --- --- --- --- --- --- ---
0 Trim Adjust --- --- --- --- --- --- --- ---
OFF OFF
--- --- --- --- --- --- --- ---
Plus 10% --- --- --- --- --- --- --- --- ON OFF --- --- --- --- --- --- --- ---
Minus 10% --- --- --- --- --- --- --- --- OFF ON --- --- --- --- --- --- --- ---
0 Trim Adjust --- --- --- --- --- --- --- --- ON ON --- --- --- --- --- --- --- ---
90 Seconds --- --- --- --- --- --- --- --- --- --- OFF OFF --- --- --- --- --- ---
120 Seconds --- --- --- --- --- --- --- --- --- --- ON OFF --- --- --- --- --- ---
150 Seconds --- --- --- --- --- --- --- --- --- ---
OFF ON
--- --- --- --- --- ---
180 Seconds --- --- --- --- --- --- --- --- --- --- ON ON --- --- --- --- --- ---
1 Stage Stat* --- --- --- --- --- --- --- --- --- --- --- ---
OFF
--- --- --- --- ---
2 Stage Stat** --- --- --- --- --- --- --- --- --- --- --- --- ON --- --- --- --- ---
1-Stage
Compressor
--- --- --- --- --- --- --- --- --- --- --- --- --- OFF --- --- --- ---
2-Stage
Compressor
--- --- --- --- --- --- --- --- --- --- --- --- --- ON
--- --- --- ---
Disabled --- --- --- --- --- --- --- --- --- --- --- --- --- ---
OFF --- --- ---
Enabled --- --- --- --- --- --- --- --- --- --- --- --- --- --- ON
--- --- ---
Disabled --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- OFF
--- ---
Enabled --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
ON --- ---
Disabled --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- OFF
---
Enabled --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
ON ---
Disabled --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- OFF
Enabled --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- ---
ON
---
Not applicable (Indicates factory setting)
* or CTK02, CTK03
Communicating thermostats are used only with Bias, Pull Up, Pull Down dip switches.
** or CTK01
3
T-Stat Heat
Compressor
Dehum
Bias
Pull Up
Pull Down
1
2
Adjust
Taps
Heat Off
Delay
Cooling Speed
Tap
Heating
Speed
Tap
Continuous
Fan
Speed
Tap
Cooling
Ramping
Switch
Bank
Purpose Function
DIP Switch