Submittal Sheet
Product SPecificationS
4 www.goodmanmfg.com SS-GMSS96
SS-GMSS96 www.goodmanmfg.com 5
SpeCiFiCationS - GCSS96
¹ Natural Gas BTU/h
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• " FPT
•
•
and noise issues.
•
over clearances from the enclosure where accessibility clearances are greater.
GCSS96
0402BNA
GCSS96
0603BNA
GCSS96
0804CNA
GCSS96
1005CNA
GCSS96
1205DNA
High Fire Input¹ 40,000 60,000 80,000 100,000 120,000
High Fire Output¹ 38,400 57,600 76,800 95,000 114,000
AFUE² 96 96 96 95 95
Temperature Rise Range (°F) 25 - 55 35 - 65 35 - 65 40 - 70 45 - 75
Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 3"
No. of Burners 2 3 4 5 6
Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 2.5 - 4 3 - 5 3 - 5
Size (D x W) 10" x 8" 10" x 8" 10" x 10" 11" x 10" 11" x 11"
Horsepower @ 1075 RPM
½ ¾ ¾
Speed 4 4 4 4 4
Permanent 427 512 683 768 844
Disposable 213 256 341 384 422
Min. Circuit Ampacity 9.6 9.6 11.7 13.7 13.7
15 15 15 15 15
111 114 139 142 154