GC9C96 Installation Manual

37

0.1 0.2
0.3
0.4 0.5
0.6 0.7 0.8
CFM CFM CFM CFM CFM CFM CFM CFM
F01 727 677 623 565
510 455 403 351
F02
923 882
841
798 752 704 660 614
F03
632 574
510
448 388 332 277 234
F04
878 839 797 751
701 653 607 561
F05
1106 1076 1044 1010
974 939 899 860
F06
1188 1156
1123
1091 1062 1029 998 964
F07
1237
1205
1174
1145 1115 1081 1050 1016
F08
1281 1252 1222 1195
1163 1134 1104 1071
F09
1382
1354 1327 1302
1276 1246 1219 1190
F01
1167 1118
1069
1022 974 928 877 833
F02
1332
1289
1245
1200 1160 1120 1081 1036
F03
680 609 532 460
397 337 252 201
F04
903 839
783
719 661 601 546 497
F05
1248 1204
1159
1113 1071 1028 983 943
F06
963
907
852
803 745 689 639 587
F07
1393 1348 1309 1267
1230 1189 1152 1116
F08
1450 1407
1366
1330 1290 1251 1221 1186
F09
1468
1436 1393 1359 1323 1285 1248 1210
F01
1167
1124
1087
1040
995 954 916 869
F02
1317 1277
1240 1201 1161 1122 1081 1045
F03
733
669 606 543 482 424 372 300
F04
1217
1174
1130 1086
1045 1003 962 925
F05
1300 1263
1225
1186
1142 1099 1062 1023
F06
919
872
820
764
711 658 605 553
F07
1126 1085 1042 998 953 910 866 824
F08
1375
1341 1301 1264 1226 1189 1154 1118
F09
1440
1402 1366 1330 1295 1260 1224 1187
F01
1366
1307
1248
1188
1130 1069 1007 938
F02
1833
1785
1736 1688
1640 1593 1543 1497
F03
1295 1230 1168 1105 1044 981 911 843
F04
1634
1578 1525 1471 1416 1363 1311 1265
F05
2028 1994
1937
1899
1863 1814 1769 1724
F06
1773 1721
1671 1621 1571 1521 1470 1421
F07
1908 1860
1813 1766
1720 1672 1624 1578
F08 1965 1919
1873
1829
1783 1736 1688 1643
F09 2096 2053 2014 1973 1931 1890 1849 1803
NOTE:
FURNACE MODEL
Y2 Y1
*C9C961005CN* F07 F03
FAN & COOLING AIRFLOW
RECOMMENDED AIRFLOW SPEEDS FOR
CONNECTION WITH 2 STAGE OUTDOOR MODELS
1. F04 is Default Speed for Y/Y1
2. F05 is Default Speed for Y2
3. F03 is Default Speed for G
MODEL
Y/Y1 , Y2 , G
*C9C960403BN
*C9C960603BN
*C9C960803BN
*C9C961005CN
TAP #
EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)
Y/Y1 , Y2 , G
Y/Y1 , Y2 , G
Y/Y1 , Y2 , G
4. For a single-stage outdoor unit, the Y connection from the thermostat can be
connected to the Y/Y1 or Y2 connection on the furnace control module. A call for
cooling will energize that connection on the furnace control module. The desired
cooling fan speed should be adjusted for the furnace control module connection
used (Y1 or Y2) to provide the correct cooling airflow.
THERMOSTAT
CALL