Daikin EHK Specification Sheet
4 www.daikincomfort.com SS-DEHK
SS-DEHK www.daikincomfort.com 5
Product SPecificationS
Product SPecificationS
electric Heat Kits for Dcc/DcH PacKageD uNits — 7½ to 12½ toNs
Dcc 7½- to 12½-toN uNits — Heat Kit usage DcH 7½- to 12½-toN uNits — Heat Kit usage
Three-Phase Units @ 208 / 240V Three-Phase Units @ 208 / 240V
Model MCA¹
MOP²
(amps)
kW &
BTU/h
Recommended
Airflow Range
Model MCA¹
MOP²
(amps)
kW &
BTU/h
Recommended
Airflow Range
DCC090***3B*** 40 50 DCH090***3B*** 40 50
EHK3-16 48 / 55 50 / 60 15 3000-3375 CFM EHK3-16 74 / 85 80 / 90 15 3000-3375 CFM
EHK3-30 87 / 100 90 / 100 30 3000-3375 CFM EHK3-30 113 / 130 120 / 150 30 3000-3375 CFM
EHK3-45 121 / 139 125 / 150 43 3000-3375 CFM EHK3-45 147 / 169 150 / 175 43 3000-3375 CFM
DCC102***3B*** 43 50 DCH102***3B*** 43 50
EHK3-16 55 60 15 3400 - 3825 CFM EHK3-16 88 90 15 3400 - 3825 CFM
EHK3-30 100 100 30 3400 - 3825 CFM EHK3-30 133 150 35 3400 - 3825 CFM
EHK3-45 139 150 43 3400 - 3825 CFM EHK3-45 173 175 43 3400 - 3825 CFM
DCC120***3B/V*** 49 60 DCH120***3B/V*** 49 60
EHK3-16 48 / 55 50 / 60 15 3,500-4,500 CFM EHK3-16 81 / 94 90 / 100 15 3,500-4,500 CFM
EHK3-30 87 / 100 90 / 100 30 3,500-4,500 CFM EHK3-30 122 / 139 125 / 150 35 3,500-4,500 CFM
EHK3-45 121 / 139 125 / 150 43 4,000-4,500 CFM EHK3-45 154 / 178 175 / 200 43 4,000-4,500 CFM
DCC150***3B*** 65 80 DCH150***3B*** 65 80
EHK3-16 65 80 15 4,000-5,600 CFM EHK3-16 110 110 15 4,000-5,600 CFM
EHK3-30 102 110 30 4,300-5,600 CFM EHK3-30 155 175 30 4,300-5,600 CFM
EHK3-45 141 150 43 4,500-5,600 CFM EHK3-45 194 200 43 4,500-5,600 CFM
480-Volt Units @ 480V 480-Volt Units @ 480V
Model MCA¹
MOP²
(amps)
kW &
BTU/h
Recommended
Airflow Range
Model MCA¹
MOP²
(amps)
kW &
BTU/h
Recommended
Airflow Range
DCC090***4B*** 19 25 DCH090***4B*** 19 25
EHK4-16 27 30 15 3000-3375 CFM EHK4-16 42 45 15 3000-3375 CFM
EHK4-30 50 50 30 3000-3375 CFM EHK4-30 64 70 30 3000-3375 CFM
EHK4-45 70 70 43 3000-3375 CFM EHK4-45 84 90 43 3000-3375 CFM
DCC102***4B*** 20 25 DCH102***4B*** 20 25
EHK4-16 27 30 15 3400 - 3825 CFM EHK4-16 42 45 15 3400 - 3825 CFM
EHK4-30 50 50 30 3400 - 3825 CFM EHK4-30 65 70 30 3400 - 3825 CFM
EHK4-45 70 70 43 3400 - 3825 CFM EHK4-45 84 90 43 3400 - 3825 CFM
DCC120***4B/V*** 24 30 DCH120***4B/V*** 24 30
EHK4-16 27 30 15 3,500-4,500 CFM EHK4-16 46 50 15 3,500-4,500 CFM
EHK4-30 50 50 30 3,500-4,500 CFM EHK4-30 69 70 30 3,500-4,500 CFM
EHK4-45 70 70 43 4,000-4,500 CFM EHK4-45 89 90 43 4,000-4,500 CFM
DCC150***4B*** 31 40 DCH150***4B*** 31 40
EHK4-16 31 40 15 4,000-5,600 CFM EHK4-16 54 60 15 4,000-5,600 CFM
EHK4-30 51 60 30 4,300-5,600 CFM EHK4-30 76 80 30 4,300-5,600 CFM
EHK4-45 71 80 43 4,500-5,600 CFM EHK4-45 96 100 43 4,500-5,600 CFM
¹ Minimum Circuit Ampacity ¹ Minimum Circuit Ampacity
² Maximum Overcurrent Protecon device ² Maximum Overcurrent Protecon device