CSCF R-22 Service Manual
PRODUCT IDENTIFICATION
10
Model # Description
GSH140**1AA
G
oodman® Brand
S
plit
H
eat Pump 14 Seer heat pump units. Initial release.
GSH140**1AB
G
oodman® Brand Split Heat Pump 14 Seer heat pump units. Screw locations
moved in the top panel, base pans, louvers, and control box covers.
GSH140**1AC
G
oodman® Brand
S
plit
H
eat Pump 14 Seer heat pump units. Releases
models with the Broad Ocean motor.
GSH140361AF,
GSH140421-48AD
GSH140601AE
G
oodman® Brand Split Heat Pump 14 Seer heat pump units. Releases
models that replace TXV & compensator with flowrator & accumulator.
Model # Description
ASH130**1AA
A
mana® Brand Split Heat Pump 13 Seer heat pump units. Initial release new
models of Amana® Brand Deluxe 13 Seer R-22 heat pumps.
ASH130**1AB
A
mana® Brand Split Heat Pump 13 Seer heat pump units. New revisions have
screw locations moved in the top panel, base pans, louvers, and control box
covers.
ASH130**1AC
A
mana® Brand Split Heat Pump 13 Seer heat pump units. New revisions have
horizontal style louvers.
Model # Description
VSH1318-601AA
V
alue Split Heat Pump 13 Seer heat pump units. Introduces Value 13 Seer HP R-
22 models. 2 year parts & 5 year compressor warranty in Bahama Beige.
Split System Heat Pumps R-22
Split System Heat Pumps R-22
Split System Heat Pumps R-22
Model # Description
GSH130363AE
GSH130483AE
GSH130603AC
G
oodman® Brand Split Pump 13 Seer condensing units. Release models holding
charge only; MODELS DO NOT CONTAIN REFRIGERANT. Units must be
evacuated and charged with R-22 per the installation instructions.
GSH130363AF
G
oodman® Brand Split Pump 13 Seer condensing units. Release of Goodman 13
SEER Condensers with updated serial plates (MCA and compressor RLA/LRA
ratin
g
s
)
.
GSH130363AG
G
oodman® Brand Split Pump 13 Seer condensing units. Goodman 13 SEER
Condensers. The current four piece louver assembly has changed to a two piece
louver plus a corner post on Goodman and value series 26" and 29" chassis.
GSH130484AC
GSH130604AC
G
oodman® Brand
S
plit
P
ump 13 Seer condensing units. Release 460V models with
holding charge only;
MODELS DO NOT CONTAIN REFRIGERANT
. Units must be
evacuated and charged with R-22 per the installation instructions.
GSH130483BA
GSH130484AD
G
oodman® Brand
S
plit
P
ump 13 Seer condensing units;
MODELS DO NOT
CONTAIN REFRIGERANT. Units must be evacuated and charged with R-22 per
the installation instructions. Replacing Copeland ZRK3 series compressors with
ZRK5 series.
GSH130483BB
G
oodman® Brand
S
plit
P
ump 13 Seer condensing units;
MODELS DO NOT
CONTAIN REFRIGERANT. Units must be evacuated and charged with R-22 per
the installation instructions. The current four piece louver assembly has changed to
a two piece louver plus a corner post on Goodman and value series 26" and 29"
chassis.
GSH130484AE
G
oodman® Brand Split Pum p 13 Seer con densin
g
units; MODELS DO NOT
CONTAIN REFRIGERANT. Units must be evacuated and charged with R-22 per
the installation instructions. The current four piece louver assembly has changed to
a two piece louver plus a corner post on Goodman and value series 26" and 29"
chassis.
Split System Heat Pumps R-22