Submittal Sheet

PRODUCT SPECIFICATIONS
2 www.goodmanmfg.com SS-GCoil
NOMENCLATURE
Product Category Engineering
C Indoor Coil Major/Minor Revisions
Application Refrigerant
A Upflow/Downflow Coil 6 R-22 or R-410A
H Horizontal A Coil 2 R-22
S Horizontal Slab Coil 4 R-410A
Nominal Width for Gas Furnace
Cabinet Finish A Fits 14” Furnace Cabinet
U Uncased B Fits 17½” Furnace Cabinet
P Painted C Fits 21” Furnace Cabinet
C Unpainted D Fits 24½” Furnace Cabinet
N Does Not Apply (horizontal slab coil)
Expansion Device
F Flowrator Nominal Capacity Range @ 13 SEER
1824 1½ to 2 Tons
3030 2½ Tons
3642 3 to 3½ Tons
11,12
AAA
2
1824
5,6,7,8
F
49
A
101
CU
3
6
ACCESSORIES
DRAIN PAN KITS
Drain Pan Kits Furnace Size
HTP-A 14” furnaces
HTP-B 17½” furnaces
HTP-C 21” furnaces
HTP-D 24½” furnaces
EXPANSION VALVE KITS
Kit Number Description Application Refrigerant
Tonnage:
Outdoor Unit
XVB18-36C 20% Bleed Valve AC Only R-22 1½ - 3 Ton
XVB42-60C 20% Bleed Valve AC Only R-22 3½ - 5 Ton
XV18-36C Non-bleed Valve AC Only R-22 1½ - 3 Ton
XV42-60C Non-bleed Valve AC Only R-22 3½ - 5 Ton
TX2N2 Non-bleed Valve AC or HP R-22 1½ - 2 Ton
TX3N2 Non-bleed Valve AC or HP R-22 2½ - 3 Ton
TX5N2 Non-bleed Valve AC or HP R-22 3½ - 5 Ton
TX2N4 Non-bleed Valve AC or HP R-410A 1½ - 2 Ton
TX3N4 Non-bleed Valve AC or HP R-410A 2½ - 3 Ton
TX5N4 Non-bleed Valve AC or HP R-410A 3½ - 5 Ton
Note: Condensing units and heat pumps with reciprocating compressors require the use of
start-assist components when used in conjunction with an indoor coil using a non-bleed
thermal expansion valve refrigerant metering device.