ASPT Service Manual
Table Of Contents
- IMPORTANT INFORMATION
- PRODUCT IDENTIFICATION
- Checking Voltage
- Checking Wiring
- Checking Thermostat And Wiring
- Thermostat Wiring
- Checking Transformer And Control Circuit
- Checking Contactor And/Or Relays
- Checking Contactor Contacts
- Checking Fan Relay Contacts
- Checking Loss Of Charge Protector (Heat Pump Models)
- Checking High Pressure Control
- Checking Low Pressure Control
- Copeland Comfort Alert™ Diagnostics - 3-Wire module
- Copeland Coresense™ Diagnostics - 3-Wire module
- Checking Capacitor
- Resistance Check Using A Digital Multi-Meter
- Capacitance Check Using A Digital Multi-Meter (In Capacitance Mode)
- Testing a Run Capacitor Under Load
- Checking Outdoor Fan and Blower Motors (PSC Motors)
- Checking Fan and Blower Motor (ECM Motors)
- Checking ECM Motor Windings
- ECM CFM Adjustments MBE/AEPF
- Blower Performance Data
- Checking High Efficiency Motors
- EEM Blower Replacement
- MBR/AR*F Electronic Blower Time Delay Relay
- Checking Compressor
- Resistance Test
- Ground Test
- Unloader Test Procedure
- Operation Test
- Checking 3-Phase Scroll Compressor Rotation
- Testing Crankcase Heater (Optional Item)
- Checking Reversing Valve and Solenoid
- Testing Defrost Control
- Testing Defrost Thermostat
- Checking Heater Limit Control(s)
- Checking Heater Elements
- Electric Heater (Optional Item)
- Checking Heater Limit Control(s)
- Checking Heater Elements
- Refrigeration Repair Practice
- Leak Testing (Nitrogen or Nitrogen-Traced)
- Evacuation
- Charging
- Checking Compressor Efficiency
- Overfeeding
- Underfeeding
- Checking Superheat
- Subcooling on Expansion Valve System
- Checking Expansion Valve Operation
- Checking Restricted Liquid Line
- Overcharge Of Refrigerant
- Non-Condensables
- Compressor Burnout
- Refrigerant Piping
- Duct Static Pressures
- Single Piece Air Handler External Static
- Two Piece Air Handler External Static Pressure
- Furnace External Static Pressure
- Periodic Maintenance
PRODUCT IDENTIFICATION
25
Model/Rev Description
GSX130**1AA Initial release of Goodman 13 SEER R-410A Condensers with Regal Beloit motors
GSX13061[1/3/4]AA
Introduction of Goodman 13 SEER R-410A Condensers that supplement our current 5 ton
models.
GSX130363AB
GSX130484AB
GSX130603AB
GSX130604AB
Changed from the current four piece louver assembly, to a two piece louver plus a corner
post on Goodman and value series 26" and 29" chassis.
GSX130**1AB Broad Ocean motors.
GSX130483AB 3 Phase model with new 6 pole motor.
GSX130483AC
3 phase model changing from the current four piece louver assembly, to a two piece louver
plus a corner post on Goodman and value series 26" and 29" chassis.
GSX130181EA
GSX130181EB
Introduction of 1.5 ton condenser with Rechi Compressor.
GSX130**1BA
GSX130**3AA
GSX130**4AA
Introduction of Goodman 13 SEER R-410A Condensers using SmartCoil® coils. Units will
have new louvers because units are smaller. Piston size change. Other components
unchanged.
GSX130301BB Replaced fan motor to -294 and fan blade to -18 on GSX130301BA models.
GSX130[42, 48]1BC
GSX130301BC
GSX130601BB
Changed from the current four piece louver assembly, to a two piece louver plus a corner
post on Goodman and value series 26" and 29" chassis.
GSX130[42, 48]1BB New 6 pole motor/fan combination.
GSX130181CA Rotary compressor.
GSX130421CA
GSX130481CA
Introduction of Goodman 3.5 and 4 ton 13 SEER condensing units with reciprocating
compressor.
GSX130361CA Replaced current compressor with compressor ZP29K5EPFV130.
GSX130[18-36]1DA Condenser conversion to 23" chassis for the 1.5 - 3 ton models.
GSX130181ED
Changed from a 4 leg Rechi Compressor 50N382XV-ZAKM to 3 Leg Rechi Compressor
50N382XV-5AKM. Changed Suction line Assy from 0210R01608 to 0210R01406. This
minor
GSX13031DB
Improved coil circuit assembly for greater capacity/efficiency and a new discharge tubing
assembly.
GSX130361EA Introduction of Goodman 3 ton conversion from 29" chassis to 26".
GSX130361EB
Changed from the current four piece louver assembly, to a two piece louver plus a corner
post on Goodman and value series 26" and 29" chassis.
GSX130371AA Improved decibel ratings for Canadian market.
GSX130181EF Change from motor 0131M00276 to 0131M00593 on units GSX130181 & VSX130181
GSX130363AD Change from copper wound motor to aluminum wound motor.
GSX130241EC
GSX130301BF
Create new Motor & Replace 0131M00294 with 0131M00800
GSX13
GOODMAN BRAND SPLIT X-R410A CONDENSERS 13 SEER
*GSX13 Continued on the next page