156
VSX130[18-48/61]1A* / VSX130{24/36/42-60]1B*/1D*,
VSX130[30]1D*/VSX130[36]1E*/ VSX140[18-60]1A*/VSX130[18-48/61]1A*
VSX130[24/36/42-60]1B*/1D*/VSX130[30]1D*/ VSX130[36]1E*
USEN.E.C. CLASS2WIRE
COMP
ALTERN ATE DOUBLE
POLE CONTACTORONLY
IO
T1
C
M
A
I
N
R
A
U
X
5
S
SR
SA
2
1
RCCF
SC
T2
C
L1
L2
(IFUSED)
CH
C
F
M
A
I
N
A
U
X
C
C
0140R00015P-C
BL
Y
C
LVJB
COL
OR C
O
DE
BK ---------------BLACK
BL ---------------BLU E
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL ---------------- YELLOW
CONTROLBOX
COMP
O
NE NT CO DE
C--------------- CONTACTOR
CM ------------ OUTDOORFAN MOTOR
COMP-------- COMPRESSOR
IO --------------INTERNALOVERLOAD
LVJB ----------LOW VOLTAGEJUNCTION BOX
RCCF --------- RUN CAPACITOR FOR COMPRESSOR &FAN
SA ------------- STARTASSIST
SC ------------- START CAPACITOR FOR COMPRESS OR (OPTIONAL)
SR ------------- START RELAYFOR COMPRESSOR (OPTIONAL)
CONTROLSSHOWN WITH THERMOSTAT IN 'OFF' POSITION.
OUTDOORPOWER SUPPLY
SEERATINGPLATE
WIRING CO
DE
FACTOR
Y WIRING
HIGH VOLT AGE
LOWVOLTAGE
OPTIONAL HI GH VOLTAGE
FI
E
LD
WIRING
HIGH VOLT AGE
IO
CM
Y
YL
YL
C
R
S
RD
BK
AUX
MAIN
COMP
SEENOTE1
SC
RD
BL
RCCF
YL
PU
YL
SR
5
2
1
BK
YL
BL
RD
YL
BL
RD
RD
BK
BK
BK
C
T1
L1
T2
L2
SA
(IFUSE D)
NOTE 2
EQUIPMENT GROUND
SEE NOTE 3
PU
BR
BK
MAIN
AUX
CM
IO
T1
L1
T2
L2
ALTERN ATE DOUBLE POLE
CONTACTOR
NOTES:
1) TO INDOOR UNIT LOWVOLTAGE TERMINAL BLOCK&
INDOOR THERMOSTAT.
2) STARTASSISTFACTORY EQUIPPED WHEN REQUIRED.
3) USE COPPER CONDUC TORS ONLY.
CFH
RD
RD
RD
BR
SEENOTE1