ARUF ASPT Installation Instructions

4
6 Installation Location
NOTE: These air handlers are designed f or indoor installa-
t ion only.
The ARUF**14** and ASPT**14** product lines may be inst alled
in one of t he upf low, downflow, horizont al lef t or horizont al
right orient at ions as shown in Figures 2, 3, 4 and 5. The unit
may be inst alled in upfl ow or horizont al lef t orient at ion as
shipped (ref er t o specif ic sect ions f or more inf ormat ion).
No f ield modif icat ions are mandat ory. However, t o obt ain
maximum ef ficiency, t he horizont al drip shield, side drain
pan and drain pan ext ension can be removed.
Side Drain Pan and Extension Removal: Ref er t o Figure 1,
remove t he t wo (2) screws t hat secure t he drip shield sup-
port bracket s t o t he condensat e collect ors (front and back).
Unsnap t he side drain pan f rom t he bot t om drain pan using
a screw driver or any small lever. The side drain pan, drip
shield bracket s and t he drain pan ext ension may now be
removed. From Figure 1, drain port labeled (A) is t he pri-
mary drain f or t his applicat ion and condensat e drain line
must be at t ached t o t his drain port . Drain port (a) is f or t he
secondary drain line (if used).
D
rip Pan
E
xtension
Side
Drain
Pan
Screw
B
b
A
Main Drain Pan
Drip Shield Bracket
Drip Shield
Pna
SIDE DRAIN PAN REMOVAL
Figure 1
6.1 Upflow Installat ion
No f ield modif icat ions are mandat ory.
6.2 Horizontal Left Inst allat ion
No f ield modif icat ions are permissible f or t his applicat ion.
Inst all unit as shown in Figure 4.
Remove red plugs f rom side drain pan bef ore connect ing con-
densat e drain pipes. Use removed plug t o close drain port s
on vert ical drain pan. The bot t om right drain connect ion in
side drain pan is t he primary drain for t his applicat ion and
condensat e drain line must be at t ached t o t his drain connec-
t ion. The bot t om lef t drain connect ion in side drain pan is for
t he secondary drain line (if used).
In applicat ions where t he air handler is inst alled in t he hori-
zont al lef t posit ion, and t he ret urn air environment see hu-
midit y levels above 65% relat ive humidit y coupled wit h
t ot al ext ernal st at ic levels above 0. 5” e. s. p. , a condensat e
kit is available for f ield applicat ion. Kit nomenclat ure can
be f ound in Table 1.
CMK0008
Condensate
Kit
CMK0009
Condensate
Kit
CMK0010
Condensate
Kit
CMK0011
Condensate
Kit
CMK0012
Condensate
Kit
CMK0013
Condensate
Kit
CMK0014
Condensate
Kit
ARUF25B14 ARUF31B14 ARUF37C14 ARUF47D14 ARUF61D14 ASPT33C14 ASPT49C14
ARUF29B14 ASPT29B14 ARUF37D14 ASPT49D14 ASPT39C14
ASPT25B14 ASPT37B14 ARUF43C14 ASPT61D14
ARUF43D14
ARUF49C14
ARUF49D14
ASPT37C14
ASPT47C14
ASPT47D14
ASPT59C14
CONDENSATE KIT
Table 1
6.3 Horizontal Right Inst allat ion / Downflow Inst allat ion
When inst alling unit in t he downf low posit ion t he appropriat e
(DFK) downf low kit is required t o prevent coil pan sweat -
ing” . The DFK kit is not supplied wit h t he air handl er and is
available t hrough your l ocal dist ribut or. See Table 2 f or t he
correct DFK and f ollow t he inst ruct ions provided f or inst alla-
t ion.
Side drain pan ext ension must be removed in t he downf low
and horizont al right applicat ions f or all model s except :
ARUF47D14**, ARUF61D14**, ASPT61D14**, ASPT49D14**.
Ref er t o Figur e 6 and 7 f or t he locat i on of t he compo-
nent s r ef erenced in t he f ol lowi ng st eps.
DFK-B
DOWNFLOW KIT
DFK-C
DOWNFLOW KIT
DFK-D
DOWNFLOW KIT
ARUF25B14** ARUF37C14* * ARUF37D14**
ARUF29B14** ARUF43C14* * ARUF43D14**
ARUF31B14** ARUF49C14* * ARUF47D14**
ASPT25B14** ASPT33C14* * ARUF49D14**
ASPT29B14** ASPT37C14* * ARUF61D14**
ASPT35B14** ASPT39C14* * ASPT61D14**
ASPT37B14** ASPT47C14* * ASPT47D14**
ASPT49C14* * ASPT49D14**
ASPT59C14* *
M ODEL LIST FOR DOW NFLOW KIT
DOWNFLOW KIT
Table 2