ARUF ASPT Installation Instructions
23
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING.
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
WARNING
Wiring is subj ect t o change. Always ref er t o t he wiring diagram on t he unit f or t he most up-t o-dat e wiring.
120/240VA
C
TST A
T
OPTIONAL
SPEEDU
P
24 VAC
SYS TEM
T RAN SF OR ME
R
C
SPEEDU
P
XFM
R
-
C
XFM
R
-
R
R
B13707-35
WI RING DI AGRA
M
M1
PARK TERMINA
L
K1
K1
FOR USE WITH
NEUTRA
L
G
HEAT KI
T
MOT O
R
The Elect ronic Blower Time Delay Relay provides power t o t he blower mot or wit h a delay of 7
seconds af t er 24VAC is applied t o “ G” . Aft er 24VAC is removed f rom “ G” , t he blower mot or
out put is de-energized af t er a delay of 65 seconds.
Normal Time Delays 60Hz 50Hz
Turn On Delay 7.0 SEC.±1% 8.4 SEC. .±1%
Turn Off Delay 65.0 SEC.±1% 78.0 SEC. .±1%
Field test mode: Short ing t he “ speedup” quick connect t o “ C” decrease t imes as f ollows:
Speedup Times 60Hz 50Hz
Turn On Delay 3.0 SEC.±1% 3.6 SEC. .±1%
Turn Off Delay 5.0 SEC.±1% 6.0 SEC. .±1%
Field t est mode is cancelled when t he “ speedup” quick connect t o “ C” short is removed.
ELECTRONIC BLOWER TIME DELAY RELAY