Specifications

Product SPecificationS
2 www.goodmanmfg.com SS-GASPT
noMenClATure
Brand Engineering*
ASinglePieceAirHandler Major/MinorRevisions
*Notusedforinventorymanagement
UnitApplication
CCeilingMountPSCMotor RefrigerantCompatability
RMultiPositionPSCMotor 4=R410A
SMultiPositionEEMMotor
WWallMountPSCMotor Electrical
1208/240V,1Phase,60Hz
CabinetFinish
UUnpainted NominalWidth
PPainted B17½”Wide
NUncased C21”Wide
D24½”Wide
ExpansionDevice
FFlowrator NominalCapacityRange
TExpansionValve 24=2Tons 42=3½Tons
30=2½Tons 48=4Tons
36=3Tons 60=5Tons
A
S
P
T
24
C
1
2
3
4
5,6
7
9
10,11
61=5Tons
1
4
AA
8
HKS X 03 X A AA
UnitType Major&MinorRevisions
HKSAHHeaterKit
Phase
CircuitBreaker A208VAC/1Ø D208VAC/3Ø
XNocircuitbreaker B240VAC/1Ø E240VAC/3Ø
CCircuitBreaker C208/240VAC/1Ø F208/240VAC/3Ø
G460VAC/3Ø
kW
033.0kW 1514.4kW CabinetSize(MAX)
054.8kW 1919.2kWw/150Flimit CCCabinet
066.0kW 2019.2kWw/170Flimit DDCabinet
088.0kW 2525.0kW XAllCabinetSizes
109.6kW
HeATing kW CorreCTion FACTor
 240 230 220 210 208
 1.00 0.92 0.84 0.77 0.75
Multiply the 240-volt heating capacity by correction factors.