ASPT Service Manual
Table Of Contents
- IMPORTANT INFORMATION
- PRODUCT IDENTIFICATION
- Checking Voltage
- Checking Wiring
- Checking Thermostat And Wiring
- Thermostat Wiring
- Checking Transformer And Control Circuit
- Checking Contactor And/Or Relays
- Checking Contactor Contacts
- Checking Fan Relay Contacts
- Checking Loss Of Charge Protector (Heat Pump Models)
- Checking High Pressure Control
- Checking Low Pressure Control
- Copeland Comfort Alert™ Diagnostics - 3-Wire module
- Copeland Coresense™ Diagnostics - 3-Wire module
- Checking Capacitor
- Resistance Check Using A Digital Multi-Meter
- Capacitance Check Using A Digital Multi-Meter (In Capacitance Mode)
- Testing a Run Capacitor Under Load
- Checking Outdoor Fan and Blower Motors (PSC Motors)
- Checking Fan and Blower Motor (ECM Motors)
- Checking ECM Motor Windings
- ECM CFM Adjustments MBE/AEPF
- Blower Performance Data
- Checking High Efficiency Motors
- EEM Blower Replacement
- MBR/AR*F Electronic Blower Time Delay Relay
- Checking Compressor
- Resistance Test
- Ground Test
- Unloader Test Procedure
- Operation Test
- Checking 3-Phase Scroll Compressor Rotation
- Testing Crankcase Heater (Optional Item)
- Checking Reversing Valve and Solenoid
- Testing Defrost Control
- Testing Defrost Thermostat
- Checking Heater Limit Control(s)
- Checking Heater Elements
- Electric Heater (Optional Item)
- Checking Heater Limit Control(s)
- Checking Heater Elements
- Refrigeration Repair Practice
- Leak Testing (Nitrogen or Nitrogen-Traced)
- Evacuation
- Charging
- Checking Compressor Efficiency
- Overfeeding
- Underfeeding
- Checking Superheat
- Subcooling on Expansion Valve System
- Checking Expansion Valve Operation
- Checking Restricted Liquid Line
- Overcharge Of Refrigerant
- Non-Condensables
- Compressor Burnout
- Refrigerant Piping
- Duct Static Pressures
- Single Piece Air Handler External Static
- Two Piece Air Handler External Static Pressure
- Furnace External Static Pressure
- Periodic Maintenance
PRODUCT IDENTIFICATION
16
Model/Rev Description
ANZ130[18-60]1AA Initial release of Amana® Brand Split System Base Heat Pump, 13 Seer R-410A units.
ANZ130[18/24/30]1AB Reversing valve change from Dunan to new SanHua reversing valve
ANZ130481AB Ranco 0151M00020 reversing valve changed to new SanHua 0151R00070 reversing valve
ANZ130241AC Create new Motor & Replace 0131M00294 with 0131M00800
ANZ130601AB Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
ANZ130[18,30]1AC Replaced motor 0131M000266 with 0131M00811
ANZ130[36,42,48]1AC Replaced motor 0131M00018P with 0131M00813
ANZ130421AD
ANZ130421AE
Change from copper wound compressor motor to aluminum wound compressor motor.
ZP34K5EPFV130 and ZP36K5EPFV130.
ANZ13
AMANA® BRAND SPLIT SYSTEM N-BASE Z-R410A HEAT PUMP 13 SEER
Model/Rev Description
ANZ140(18-60)1AA
Introduction of ready 15, 14 SEER heat pumps to meet the 2015 energy efficiency
requirement.
ANZ140(24-30)1AB
Energy guide update.
ANZ140181AB
Minor revisions on OD units ZP14K6 compressors without hard start kit.
14S 1.5T HPs ONLY.
ANZ140421AB
ANZ140491AB
Motor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.
ANZ140[18,30]1AC
ANZ140361AB
Change from copper wound motor to aluminum wound motor.
ANZ140[42,49]1AC
ANZ140[48,60]1AB
Refrigerant Charge Reduction
ANZ140[18,30]1AD
ANZ140361AC
Refrigerant Charge Reduction
ANZ140241AD Equivalent motor with Aluminum Windings replacing Copper Windings.
ANZ140[48,60]1AC Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
ANZ14
AMANA® BRAND SPLIT SYSTEM N-BASE Z-R410A HEAT PUMP 14 SEER