Model # Description
SSX140**1AA
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Initial release of
Goodman 14 SEER AC 410A.
SSX140**1AB
S
pecial High Feature
S
plit
X
C
ondenser 14 Seer condensing units. Revisions have screw
locations moved in the top panel, base pans, louvers, and control box covers.
SSX14018, 241AC
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Revised condenser
coils by removing [1] haripin.
SSX140301AC
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Model contains the
Broad Ocean motor 0131M00060
SSX14036-601AC
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Models contain the
Broad Ocean motor 0131M00061
SSX140421AD
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Introduces
SSX140421A in 29" base pan
SSX140[18-24]1BA
SSX140[30-36]1BA
SSX140421CA
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units
.
Converts 1.5 - 3.5 ton
condenser coil tubes from 3/8" tube diameter to 5mm tube di ameter.
SSX140[18-36]1BC
SSX140421CC
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units
.
Changing from the
current four piece louver assembly, to a two piece louver plus a corner post on Goodman
and value series 26" and 29" chassis.
SSX140421BA
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Revision for
SSZ140421B* in 29 base pan and it will the reduce the unit charge from 180 oz. to 170 oz.
and replace the 1/4 hp outdoor unit motor with 1/6 hp motor.
SSX14030-421AE
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Revised condenser
coils by removing [1] haripin.
SSX140[18-48]1BA
SSX14042-481CA
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Introduction of
Goodman 14 SEER R-410A Condensers, using SmartCoil® Coils.
SSX140[18-36]1BB
SSX140421CB
SSX140601AF
S
pecial High Feature
S
plit
X
Condenser 14 Seer condensing units. Relocation of low
pressure switch from liquid line to suction line as a compressor safeguard to prevent low
pressure from entering.
SSX160**1AA
S
pecial High Feature
S
plit
X
Condenser 16 Seer condensing units. Introduces Goodman
16 SEER AC 410A
SSX160**1AB
S
pecial High Feature
S
plit
X
Condenser 16 Seer condensing units. New revisions have
screw locations moved in the top panel, base pans, louvers, and control box covers.
SSX160**1AB
SSX160591AA
S
pecial High Feature
S
plit
X
Condenser 16 Seer condensing units. New revisions have
screw locations moved in the top panel, base pans, louvers, and control box covers.
SSX160[24, 36, 48]1BA
SSX160[30 & 42]1AA
S
pecial High Feature
S
plit
X
Condenser 16 Seer condensing units. New revisions have
SmartCoil® coils.
SSX160[24 & 36]1BC
SSX160[30 & 42]1AB
S
pecial High Feature
S
plit
X
Condenser 16 Seer condensing units. Changing from the
current four piece louver assembly, to a two piece louver plus a corner post on Goodman
and value series 26" and 29" chassis.
SSX160601BA
S
pecial High Feature
S
plit
X
Condenser 16 Seer condensing units. New "BA" revision
models use ZPS49K compressor.
SSX160[24,36,60]1BB
S
pecial High Feature
S
plit
X
Condenser 16 Seer condensing units. Relocation of low
pressure switch from liquid line to suction line as a compressor safeguard to prevent low
pressure from entering.