User Manual
8 www.goodmanmfg.com SS-GMVM96
SS-GMVM96 www.goodmanmfg.com 9
Product SPecificationS
Product SPecificationS
GCVM96 airflow data — HeatiNG speeds
GCVM960604CX
ACVM960604CX
GCVM960805DX
ACVM960805DX
Minus(-) 1,098 48 Minus(-) 1,440 49
Normal 1,220 44 Normal 1,600 44
Plus (+) 1,342 40 Plus (+) 1,760 40
Minus(-) 1,206 44 Minus(-) 1,539 46
Normal 1,340 40 Normal 1,710 41
Plus (+) 1,474 36 Plus (+) 1,881 38
Minus(-) 1,314 40 Minus(-) 1,620 44
Normal 1,460 36 Normal 1,800 39
Plus (+) 1,606 33 Plus (+) 1,980 36
Minus(-) 1,431 37 Minus(-) 1,719 41
Normal 1,590 33 Normal 1,910 37
Plus (+) 1,749 30 Plus (+) 2,101 34
* @ .1" - .5" w.c. ESP * @ .1" - .5" w.c. ESP
GCVM961005DX
Minus(-) 1,557 56
Normal 1,730 51
Plus (+) 1,903 46
Minus(-) 1,593 55
Normal 1,770 49
Plus (+) 1,947 45
Minus(-) 1,656 53
Normal 1,840 48
Plus (+) 2,024 43
Minus(-) 1,683 52
Normal 1,870 47
Plus (+) 2,057 43
* @ .1" - .5" w.c. ESP
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
cooling purposes only.