User Manual

2 www.goodmanmfg.com SS-GMVM96
SS-GMVM96 www.goodmanmfg.com 3
Product SPecificationS
Product SPecificationS
speCifiCatioNs
GMVM96
0603BX
GMVM96
0805CX
GMVM96
1005DX
GMVM96
1155DX
GCVM96
0604CX
GCVM96
0805DX
GCVM96
1005DX

High Fire Input¹ 60,000 80,000 100,000 115,000 60,000 80,000 100,000
High Fire Output¹ 57,600 76,800 96,000 109,250 57,600 76,800 95,000
Low-Fire Steady-State Input¹ 30,000 40,000 50,000 57,500 30,000 40,000 50,000
Low-Fire Steady-State Output¹ 28,800 38,400 48,000 54,625 28,800 38,400 47,500
AFUE² 96 96 96 95 96 96 95
Tons AC @ 0.5” ESP 1.5-3.0 2.0-5.0 2.0-5.0 2.0-5.0 1.5-4.0 2.0-5.0 2.0-5.0
Temperature Rise Range (°F) 20-50 35-65 35-65 35-65 20-50 20-50 25-55

Size (D x W) 10" X 8" 11" X 10" 11" X 10" 11" X 10" 10"X 10" 11" X 10" 11" X 10"
Horespower @ 1050 RPM 3/4 1 1 1 3/4 1 1
Speed Variable Variable Variable Variable Variable Variable Variable
Vent Diameter³ 2" 3" 3" 3" 2" 3" 3"
No. of Burners 3 4 5 5 3 4 5
Disposable Filter (in²) 731 683 853 981 731 975 1,056

Min. Circuit Ampacity (amps) 6.0 14.2 14.2 14.2 6.0 14.2 14.2

15.0 15.0 15.0 15.0 15.0 15.0 15.0
 135 145 170 170 139 165 170
¹ Natural Gas BTU/h
² 
³ 





the same size as noted.

 All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
 
 