Product SPecificationS
Product SPecificationS
speCifiCatioNs
GMVM96
0603BX
GMVM96
0805CX
GMVM96
1005DX
GMVM96
1155DX
GCVM96
0604CX
GCVM96
0805DX
GCVM96
1005DX
High Fire Input¹ 60,000 80,000 100,000 115,000 60,000 80,000 100,000
High Fire Output¹ 57,600 76,800 96,000 109,250 57,600 76,800 95,000
Low-Fire Steady-State Input¹ 30,000 40,000 50,000 57,500 30,000 40,000 50,000
Low-Fire Steady-State Output¹ 28,800 38,400 48,000 54,625 28,800 38,400 47,500
AFUE² 96 96 96 95 96 96 95
Tons AC @ 0.5” ESP 1.5-3.0 2.0-5.0 2.0-5.0 2.0-5.0 1.5-4.0 2.0-5.0 2.0-5.0
Temperature Rise Range (°F) 20-50 35-65 35-65 35-65 20-50 20-50 25-55
Size (D x W) 10" X 8" 11" X 10" 11" X 10" 11" X 10" 10"X 10" 11" X 10" 11" X 10"
Horespower @ 1050 RPM 3/4 1 1 1 3/4 1 1
Speed Variable Variable Variable Variable Variable Variable Variable
Vent Diameter³ 2" 3" 3" 3" 2" 3" 3"
No. of Burners 3 4 5 5 3 4 5
Disposable Filter (in²) 731 683 853 981 731 975 1,056
Min. Circuit Ampacity (amps) 6.0 14.2 14.2 14.2 6.0 14.2 14.2
15.0 15.0 15.0 15.0 15.0 15.0 15.0
135 145 170 170 139 165 170
¹ Natural Gas BTU/h
²
³
the same size as noted.
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.