ProdUCt sPeCiFiCations
ProdUCt sPeCiFiCations
SS-CPG36-72 www.goodmanmfg.com 27
rooF CUrB installation — riGGinG
Provisionsforforkshavebeenincludedintheunitbaseframe.Nootherfork
locationsareapproved.
• Unitmustbeliftedbythefourliftingholeslocatedatthebaseframe
corners.
• Liftingcablesshouldbeattachedtotheunitwithshackles.
• Thedistancebetweenthecranehookandthetopoftheunitmustnotbe
lessthan60”.
• Twospreaderbarsmustspanovertheunittopreventdamagetothecabi-
netbytheliftcables.Spreaderbarsmustbeofsufcientlengthsothatca-
blesdonotcomeincontactwiththeunitduringtransport.Removewood
strutsmountedbeneathunitbaseframebeforesettingunitonroofcurb.
Thesestrutsareintendedtoprotectunitbaseframefromforkliftdamage.
Toremovethestruts,extractthesheetmetalretainersandpullthestruts
throughthebaseoftheunit.Refertorigginglabelontheunit.
Important: If using bottom discharge with roof curb, duct-work should be
attachedtothecurbpriortoinstallingtheunit.Duct-workdimensionsare
showninRoofCurbInstallationInstructionsManual.
RefertotheRoofCurbInstallationInstructionsforpropercurbinstallation.
CurbingmustbeinstalledincompliancewiththeNationalRoongContractorsAssociationManual.
Lowerunitcarefullyontoroofmountingcurb.Whileriggingtheunit,thecenterofgravitywillcausethecondenserendtobelower
thanthesupplyairend.
Bringcondenserendofunitintoalignmentwiththecurb.Withcondenserendoftheunitrestingoncurbmemberandusingcurbas
afulcrum,loweroppositeendoftheunituntilentireunitisseatedonthecurb.Whenarectangularcantilevercurbisused,takecare
tocentertheunit.Checkforproperalignmentandorientationofsupplyandreturnopeningswithduct.
Corner & Center-oF-Gravity loCations
30”
Compressor
Return
Evaporator Coil
Supply
Condenser
Coil
37”
Corner Weight (A)
100 110 115
130
Corner Weight (B)
170 180 195
215
Corner Weight (C)
105 110 120
130
Corner Weight (D)
170 180 195
215
Unit Shipping Weight 550 595 625 715
Unit Operang Weight 525 570 600 690
Note: Weights are calculated without accessories installed.