- Goodman Mfg. Co. LP. Heat Pump User Manual

prodUCt speCifiCations
prodUCt speCifiCations
SS-GPH15M www.goodmanmfg.com 9
expanded Cooling datagph1536m41a* (Cont.)
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
80
1350
MBh 35.9 36.6 39.2 41.9 35.0 35.8 38.2 40.9 34.2 34.9 37.3 39.9 33.4 34.1 36.4 38.9 31.7 32.4 34.6 37.0 29.4 30.0 32.1 34.3
S/T 0.95 0.89 0.73 0.54 1.00 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.83 0.62
∆T 23 22 19 15 24 23 20 16 23 23 20 16 23 23 20 16 22 22 19 16 20 20 18 15
kW 2.30 2.35 2.42 2.50 2.48 2.53 2.61 2.70 2.63 2.69 2.78 2.87 2.77 2.83 2.92 3.02 2.89 2.95 3.05 3.15 2.99 3.05 3.16 3.26
Amps 11.0 11.2 11.5 11.8 11.7 11.9 12.2 12.6 12.5 12.7 13.1 13.5 13.2 13.4 13.8 14.2 13.9 14.2 14.5 15.0 14.6 14.9 15.3 15.8
Hi PR 232 250 264 275 261 281 296 309 297 319 337 351 338 363 384 400 380 409 432 450 420 452 477 498
Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 126 135 147 156 133 141 154 164 137 146 159 170
1200
MBh 34.8 35.6 38.0 40.6 34.0 34.8 37.1 39.7 33.2 33.9 36.2 38.7 32.4 33.1 35.4 37.8 30.8 31.4 33.6 35.9 28.5 29.1 31.1 33.3
S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.74 0.55 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.98 0.80 0.59
∆T 24 23 20 16 25 23 20 16 25 24 20 16 25 24 21 16 24 23 20 16 22 22 19 15
kW 2.28 2.33 2.40 2.48 2.46 2.51 2.59 2.67 2.61 2.67 2.75 2.85 2.75 2.81 ## 3.00 2.86 2.93 3.02 3.13 2.96 3.03 3.13 3.24
Amps 10.9 11.1 11.4 11.7 11.6 11.8 12.1 12.5 12.4 12.6 13.0 13.4 13.1 13.3 13.7 14.1 13.8 14.0 14.4 14.9 14.4 14.7 15.2 15.6
Hi PR 230 248 261 273 258 278 293 306 294 316 334 348 334 360 380 396 376 405 428 446 416 447 472 493
Lo PR 109 115 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 140 152 162 136 144 158 168
1050
MBh 32.1 32.8 35.1 37.5 31.4 32.1 34.3 36.6 30.6 31.3 33.5
35.8 29.9 30.5 32.6 34.9 28.4 29.0 31.0 33.1 26.3 26.9 28.7 30.7
S/T 0.88 0.82 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.57 1.00 0.94 0.77 0.57
∆T 25 24 21 16 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 16 23 22 19 15
kW 2.23 2.27 2.35 2.42 2.40 2.45 2.53 2.61 2.55 2.60 2.69 2.77 2.68 2.74 2.83 2.92 2.79 2.85 2.95 3.05 2.89 2.95 3.05 3.15
Amps 10.7 10.9 11.1 11.5 11.3 11.5 11.8 12.2 12.1 12.3 12.7 13.1 12.8 13.0 13.4 13.8 13.4 13.7 14.1 14.5 14.1 14.4 14.8 15.3
Hi PR 223 240 254 265 250 269 285 297 285 306 324 338 324 349 369 384 365 393 415 433 403 434 458 478
Lo PR 105 112 122 130 111 118 129 138 116 123 134 143 121 129 141 150 127 135 148 157 132 140 153 163
85
1350
MBh 36.5 37.2 39.0 41.6 35.6 36.3 38.1 40.6 34.8 35.5 37.1 39.6 33.9 34.6 36.2 38.7 32.2 32.9 34.4 36.7 29.9 30.4 31.9 34.0
S/T 1.00 0.96 0.87 0.70 1.00 1.00 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.99 0.80 1.00 1.00 1.00 0.81
∆T 25 24 23 20 24 25 23 20 24 24 23 20 23 24 24 20 22 22 23 20 20 21 22 19
kW 2.32 2.37 2.44 2.52 2.50 2.55 2.63 2.72 2.65 2.71 2.80 2.89 2.79 2.85 2.95 3.05 2.91 2.98 3.07 3.18 3.01 3.08 3.18 3.29
Amps 11.0 11.3 11.5 11.9 11.7 12.0 12.3 12.7 12.6 12.8 13.2 13.6 13.3 13.5 13.9 14.4 14.0 14.3 14.7 15.1 14.7 15.0 15.4 15.9
Hi PR 235 253 267 278 263 283 299 312 300 322 340 355 341 367 388 404 384 413 436 455 424 456 482 503
Lo PR 111 118 129 137 117 124 136 145 122 129 141 150 128 136 148 158 134 142 155 166 138 147 161 171
1200
MBh 35.4 36.1 37.8 40.4 34.6 35.3 36.9 39.4 33.8 34.4 36.1 38.5 33.0 33.6 35.2 37.5 31.3 31.9 33.4 35.7 29.0 29.6 31.0 33.0
S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.77 1.00 1.00 0.95 0.77
∆T 26 25 24 21 26 26 24 21
26 26 24 21 25 26 25 21 24 24 24 21 22 23 23 20
kW 2.30 2.35 2.42 2.50 2.48 2.53 2.61 2.70 2.63 2.69 2.78 2.87 2.77 2.83 2.92 3.02 2.89 2.95 3.05 3.15 2.99 3.05 3.16 3.26
Amps 11.0 11.2
11.5 11.8 11.7 11.9 12.2 12.6 12.5 12.7 13.1 13.5 13.2 13.4 13.8 14.2 13.9 14.2 14.5 15.0 14.6 14.9 15.3 15.8
Hi PR 232 250 264 275 261 281 296 309 297 319 337 351 338 363 384 400 380 409 432 450 420 452 477 498
Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 126 135 147 156 133 141 154 164 137 146 159 170
1050
MBh 32.7 33.3 34.9 37.2 31.9 32.6 34.1 36.4 31.2 31.8 33.3 35.5 30.4 31.0 32.5 34.6 28.9 29.5 30.9 32.9 26.8 27.3 28.6 30.5
S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.74
∆T 26 26 24 21 27 26 25 21 27 26 25 21 27 26 25 22 25 26 25 21 23 24 23 20
kW 2.25 2.29 2.36 2.44 2.42 2.47 2.55 2.63 2.57 2.62 2.71 2.80 2.70 2.76 2.85 2.95 2.81 2.88 2.97 3.07 2.91 2.98 3.08 3.18
Amps 10.7 10.9 11.2 11.5 11.4 11.6 11.9 12.3 12.2 12.4 12.8 13.2 12.9 13.1 13.5 13.9 13.5 13.8 14.2 14.7 14.2 14.5 14.9 15.4
Hi PR 225 243 256 267 253 272 287 300 288 310 327 341 328 353 372 388 369 397 419 437 407 438 463 483
Lo PR 106 113 124 132 112 120 130 139 117 124 136 144 123 130 142 152 129 137 149 159 133 141 154 164
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions kW = Total system power
High & low pressures are measured at the liquid & sucon access ngs. Amps = outdoor unit amps (comp.+ fans)