- Goodman Mfg. Co. LP. Heat Pump User Manual

prodUCt speCifiCations
prodUCt speCifiCations
34 www.goodmanmfg.com SS-GPH15M
aUxiliary heating data (Cont.)
GPH1543M41A* GPH1548M41A*
Conditions: 1350 CFM; Indoor Air @ 70°F DB Conditions: 1700 CFM Indoor Air @ 70°F DB
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Capacity
BTU/h
COP
5K 8K 10K 15K 20K
Capacity
BTU/h
COP
5K 8K 10K 15K 20K
65 50.28 4.31 67.35 77.58 84.41 101.48 --- 65 57.38 4.00 73.76 84.69 90.15 106.53 122.91
60 47.60 4.16 64.67 74.90 81.73 98.80 --- 60 54.32 3.86 70.71 81.63 87.09 103.47 119.85
55 44.80 4.00 61.87 72.10 78.93 96.00 --- 55 51.13 3.70 67.51 78.43 83.89 100.28 116.66
50 41.88 3.82 58.95 69.18 76.01 93.08 --- 50 47.80 3.53 64.18 75.10 80.56 96.94 113.33
45 38.76 3.61 55.83 66.06 72.89 89.96 --- 45 44.23 3.34 60.62 71.54 77.00 93.38 109.76
40 36.00 3.43 53.07 63.30 70.13 87.20 --- 40 41.09 3.16 57.47 68.39 73.85 90.23 106.61
35 33.20 3.24 50.27 60.50 67.33 84.40 --- 35 37.89 2.98 54.27 65.19 70.65 87.04 103.42
30 24.92 2.53 41.99 52.22 59.05 76.12 --- 30 30.65 2.45 47.03 57.96 63.42 79.80 96.18
25 23.00 2.39 40.07 50.30 57.13 74.20 --- 25 28.29 2.32 44.67 55.59 61.05 77.44 93.82
20 21.18 2.25 38.25 48.48 55.31 72.38 --- 20 26.05 2.18 42.43 53.36 58.82 75.20 91.58
15 19.26 2.10 36.33 46.56 53.39 70.46 --- 15 23.69 2.03 40.07 50.99 56.45 72.84 89.22
10 17.28 1.93 34.35 44.58 51.41 68.48 --- 10 21.25 1.86 37.64 48.56 54.02 70.40 86.78
5 15.32 1.76 32.39 42.62 49.45 66.52 --- 5 18.84 1.69 35.23 46.15 51.61 67.99 84.37
-5 11.40 1.38 28.47 38.70 45.53 62.60 --- -5 14.02 1.32 30.40 41.33 46.79 63.17 79.55
-10 9.34 1.16 26.41 36.64 43.47 60.54 --- -10 11.49 1.11 27.87 38.79 44.25 60.64 77.02
GPH1549M41A* GPH1560M41A*
Conditions: 1700 CFM Indoor Air @ 70°F DB Conditions: 1800 CFM; Indoor Air @ 70°F DB
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Capacity
BTU/h
COP
5K 8K 10K 15K 20K
Capacity
BTU/h
COP
5K 8K 10K 15K 20K
65 57.38 4.00 73.76 84.69 90.15 106.53 122.91 65 70.39 3.93 86.77 97.70 103.16 119.54 135.92
60 54.32 3.86 70.71 81.63 87.09 103.47 119.85 60 66.64 3.79 83.02 93.94 99.40 115.79 132.17
55 51.13 3.70 67.51 78.43 83.89 100.28 116.66 55 62.72 3.64 79.10 90.02 95.48 111.87 128.25
50 47.80 3.53 64.18 75.10 80.56 96.94 113.33 50 58.63 3.48 75.01 85.94 91.40 107.78 124.16
45 44.23 3.34 60.62 71.54 77.00 93.38 109.76 45 54.26 3.29 70.65 81.57 87.03 103.41 119.79
40 41.09 3.16 57.47 68.39 73.85 90.23 106.61
40 50.40 3.11 66.78 77.70 83.16 99.55 115.93
35 37.89 2.98 54.27 65.19 70.65 87.04 103.42 35 46.48 2.94 62.86 73.78 79.24 95.63 112.01
30 30.65 2.45 47.03 57.96 63.42 79.80 96.18 30 38.88 2.52 55.26 66.18 71.64 88.02 104.40
25 28.29 2.32 44.67 55.59 61.05 77.44 93.82 25 35.88 2.38 52.26 63.18 68.64 85.03 101.41
20 26.05 2.18 42.43 53.36 58.82 75.20 91.58 20 33.04 2.24 49.42 60.34 65.81 82.19 98.57
15 23.69 2.03 40.07 50.99 56.45 72.84 89.22 15 30.05 2.08 46.43 57.35 62.81 79.19 95.58
10 21.25 1.86 37.64 48.56 54.02 70.40 86.78 10 26.96 1.92 43.34 54.26 59.72 76.10 92.49
5 18.84 1.69 35.23 46.15 51.61 67.99 84.37 5 23.90 1.74 40.28 51.20 56.66 73.05 89.43
0 16.43 1.51 32.82 43.74 49.20 65.58 81.96 0 20.84 1.56 37.22 48.15 53.61 69.99 86.37
-5 14.02 1.32 30.40 41.33 46.79 63.17 79.55 -5 17.78 1.36 34.17 45.09 50.55 66.93 83.31
-10 11.49 1.11 27.87 38.79 44.25 60.64 77.02 -10 14.57 1.15 30.95 41.87 47.34 63.72 80.10
Notes