- Goodman Mfg. Co. LP. Heat Pump User Manual

prodUCt speCifiCations
prodUCt speCifiCations
SS-GPH15M www.goodmanmfg.com 33
aUxiliary heating data
Notes
COP: Coecient of performance
To obtain BTU capacity of the unit with Kw of auxiliary heat, mulply by 1000 ( example 39.01 x 1000 = 39,010 BTU’S)
GPH1524M41A*
GPH1530M41A*
Conditions: 860 CFM; Indoor Air @ 70°F DB
Conditions: 1000 CFM; Indoor Air @ 70°F DB
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Capacity
BTU/h
COP 5K 8K 10K 15K 20K
Capacity
BTU/h
COP 5K 8K 10K 15K 20K
65 29.41 4.14 45.80 56.72 62.18 --- --- 65 34.44 4.36 51.51 61.75 68.57 85.64 ---
60 27.85 4.00 44.23 55.15 60.61 --- --- 60 32.61 4.21 49.67 59.91 66.74 83.80 ---
55 26.21 3.84 42.59 53.51 58.97 --- --- 55 30.69 4.04 47.75 57.99 64.82 81.88 ---
50 24.50 3.66 40.88 51.80 57.26 --- --- 50 28.69 3.86 45.75 55.99 62.82 79.88 ---
45 22.67 3.46 39.06 49.98 55.44 --- --- 45 26.55 3.65 43.62 53.85 60.68 77.75 ---
40 21.06 3.28 37.44 48.36 53.82 --- --- 40 24.66 3.36 41.73 51.96 58.79 75.86 ---
35 19.42 3.09 35.80 46.73 52.19 --- --- 35 22.74 3.26 39.81 50.05 56.87 73.94 ---
30 15.59 2.52 31.97 42.89 48.35 --- --- 30 18.81 2.70 35.88 46.12 52.94 70.01 ---
25 14.39 2.38 30.77 41.69 47.15 --- --- 25 17.37 2.55 34.43 44.67 51.50 68.56 ---
20 13.25 2.24 29.63 40.55 46.01 --- --- 20 15.99 2.40 33.06 43.29 50.12 67.19 ---
15 12.05 2.09 28.43 39.35 44.81 --- --- 15 9.89 2.24 26.95 37.19 44.02 61.08 ---
10 10.81 1.92 27.19 38.11 43.57 --- --- 10 8.87 2.06 25.94 36.18 43.00 60.07 ---
5 9.58 1.74 25.97 36.89 42.35 --- --- 5 7.87 1.87 24.93 35.17 42.00 59.06 ---
0 8.36 1.56 24.74 35.66 41.12 --- --- 0 6.86 1.67 23.93 34.16 40.99 58.06 ---
-5 7.13 1.36 23.51 34.43 39.90 --- --- -5 5.85 1.47 22.92 33.16 39.98 57.05 ---
-10 5.84 1.15 22.22 33.15 38.61 --- --- -10 7.05 1.23 24.12 34.36 41.18 58.25 ---
GPH1536M41A* GPH1542M41A*
Conditions: 1200 CFM; Indoor Air @ 70°F DB Conditions: 1250 CFM Indoor Air @ 70°F DB
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Outdoor
Ambient
°F.
Basic Unit w/o
Aux. Heat
Capacity of Unit
w/ kW of Aux. Heat
Capacity
BTU/h
COP 5K 8K 10K 15K 20K
Capacity
BTU/h
COP 5K 8K 10K 15K 20K
65 44.59 4.02 60.97 71.89 77.35 93.73 --- 65 50.28 4.31 67.35 77.58 84.41 101.48 ---
60 42.21 3.89 58.59 69.51 74.97 91.36 --- 60 47.60 4.16 64.67 74.90 81.73 98.80 ---
55 39.73 3.74 56.11 67.03 72.49 88.87 --- 55 44.80 4.00 61.87 72.10 78.93 96.00 ---
50 37.14 3.57 53.52 64.44 69.90 86.28 --- 50 41.88 3.82 58.95 69.18 76.01 93.08 ---
45 34.37 3.38 50.75 61.67 67.14 83.52 ---
45 38.76 3.61 55.83 66.06 72.89 89.96 ---
40 31.92 3.20 48.31 59.23 64.69 81.07 --- 40 36.00 3.43 53.07 63.30 70.13 87.20 ---
35 29.44 3.02 45.82 56.74 62.20 78.59 --- 35 33.20 3.24 50.27 60.50 67.33 84.40 ---
30 23.20 2.80 39.58 50.50 55.97 72.35 --- 30 24.92 2.53 41.99 52.22 59.05 76.12 ---
25 21.41 2.64 37.80 48.72 54.18 70.56 --- 25 23.00 2.39 40.07 50.30 57.13 74.20 ---
20 19.72 2.49 36.10 47.02 52.48 68.87 --- 20 21.18 2.25 38.25 48.48 55.31 72.38 ---
15 17.93 2.32 34.31 45.24 50.70 67.08 --- 15 19.26 2.10 36.33 46.56 53.39 70.46 ---
10 16.09 2.13 32.47 43.39 48.85 65.23 --- 10 17.28 1.93 34.35 44.58 51.41 68.48 ---
5 14.26 1.94 30.65 41.57 47.03 63.41 --- 5 15.32 1.76 32.39 42.62 49.45 66.52 ---
0 12.44 1.73 28.82 39.74 45.20 61.59 --- 0 13.36 1.58 30.43 40.66 47.49 64.56 ---
-5 10.61 1.52 27.00 37.92 43.38 59.76 --- -5 11.40 1.38 28.47 38.70 45.53 62.60 ---
-10 8.70 1.28 25.08 36.00 41.46 57.84 --- -10 9.34 1.16 26.41 36.64 43.47 60.54 ---