expanded Cooling data — gph1542m41a* – low stage
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
70
955
MBh 26.9 27.9 30.6 - 26.3 27.3 29.9 - 25.7 26.6 29.2 - 25.1 26.0 28.5 - 23.8 24.7 27.0 - 22.1 22.9 25.1 -
S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.62 0.43 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.81 0.68 0.47 -
∆T 18 16 12 - 18 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
kW 1.80 1.84 1.90 - 1.94 1.99 2.06 - 2.07 2.12 2.19 - 2.19 2.24 2.31 - 2.28 2.33 2.41 - 2.36 2.42 2.50 -
Amps 7.7 7.9 8.1 - 8.3 8.5 8.7 - 9.0 9.2 9.5 - 9.6 9.8 10.1 - 10.1 10.4 10.7 - 10.7 11.0 11.3 -
Hi PR 218 235 248 - 245 263 278 - 278 300 316 - 317 341 360 - 357 384 405 - 394 424 448 -
Lo PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 144 - 130 138 150 - 134 143 156 -
850
MBh 26.2 27.1 29.7 - 25.6 26.5 29.0 - 24.9 25.9 28.3 - 24.3 25.2 27.6 - 23.1 24.0 26.3 - 21.4 22.2 24.3 -
S/T 0.67 0.56 0.39 - 0.70 0.58 0.40 - 0.71 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.77 0.64 0.45 -
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -
kW 1.79 1.82 1.88 - 1.93 1.97 2.04 - 2.06 2.10 2.17 - 2.17 2.22 2.29 - 2.26 2.31 2.39 - 2.34 2.40 2.48 -
Amps 7.7 7.8 8.1 - 8.2 8.4 8.7 - 8.9 9.1 9.4 - 9.5 9.7 10.0 - 10.0 10.3 10.6 - 10.6 10.9 11.2 -
Hi PR 216 232 245 - 242 261 275 - 276 297 313 - 314 338 357 - 353 380 401 - 390 420 443 -
Lo PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 133 141 154 -
745
MBh 24.1 25.0 27.4 - 23.6 24.4 26.8 - 23.0 23.9
26.1 - 22.5 23.3 25.5 - 21.3 22.1 24.2 - 19.8 20.5 22.4 -
S/T 0.65 0.54 0.37 - 0.67 0.56 0.39 - 0.69 0.57 0.40 - 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.74 0.62 0.43 -
∆T 19 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
kW 1.74 1.78 1.84 - 1.88 1.92 1.99 - 2.00 2.05 2.12 - 2.11 2.16 2.23 - 2.20 2.25 2.33 - 2.28 2.34 2.42 -
Amps 7.5 7.6 7.9 - 8.0 8.2 8.5 - 8.7 8.9 9.1 - 9.2 9.4 9.7 - 9.8 10.0 10.3 - 10.3 10.6 10.9 -
Hi PR 209 225 238 - 235 253 267 - 267 288 304 - 304 328 346 - 343 369 389 - 378 407 430 -
Lo PR 103 109 120 - 109 116 126 - 113 120 131 - 119 126 138 - 124 132 144 - 129 137 149 -
75
955
MBh 27.4 28.2 30.5 32.8 26.8 27.6 29.8 32.0 26.1 26.9 29.1 31.3 25.5 26.2 28.4 30.5 24.2 24.9 27.0 29.0 22.4 23.1 25.0 26.8
S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.59 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40
∆T 21 19 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 1.82 1.86 1.92 1.98 1.96 2.01 2.07 2.14 2.09 2.14 2.21 2.29 2.20 2.26 2.33 2.41 2.30 2.36 2.44 2.52 2.39 2.44 2.53 2.61
Amps 7.8 8.0 8.2 8.5 8.4 8.6 8.8 9.1 9.0 9.3 9.5 9.9 9.6 9.9 10.2 10.5 10.2 10.5 10.8 11.2 10.8 11.1 11.4 11.8
Hi PR 220 237 250 261 247 266 281 293 281 303 320 333 320 345 364 380 360 388 409 427 398 428 452 472
Lo PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167
850
MBh 26.6 27.4 29.7 31.8 26.0 26.8 29.0 31.1 25.4 26.1 28.3 30.3 24.8 25.5 27.6 29.6 23.5 24.2 26.2 28.1 21.8 22.4 24.3 26.1
S/T 0.76 0.68 0.52 0.33 0.79 0.71 0.54 0.34 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.36 0.87 0.78 0.59 0.38 0.88 0.78 0.59 0.38
∆T 22 20 17 11 22 20 17
12 22 20 17 12 22 21 17 12 22 20 17 12 21 19 16 11
kW 1.80 1.84 1.90 1.96 1.95 1.99 2.06 2.13 2.07 2.12 2.19 2.27 2.19 2.24 2.31 2.39 2.28 2.33 2.42 2.50 2.36 2.42 2.50 2.59
Amps 7.7 7.9
8.1 8.4 8.3 8.5 8.8 9.1 9.0 9.2 9.5 9.8 9.6 9.8 10.1 10.4 10.1 10.4 10.7 11.1 10.7 11.0 11.3 11.7
Hi PR 218 235 248 259 245 263 278 290 278 300 316 330 317 341 360 376 357 384 405 423 394 424 448 467
Lo PR 107 114 124 133 113 120 131 140 118 125 137 146 124 131 144 153 130 138 150 160 134 143 156 166
745
MBh 24.6 25.3 27.4 29.4 24.0 24.7 26.7 28.7 23.4 24.1 26.1 28.0 22.8 23.5 25.5 27.3 21.7 22.3 24.2 26.0 20.1 20.7 22.4 24.0
S/T 0.74 0.66 0.50 0.32 0.76 0.68 0.52 0.33 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.84 0.76 0.57 0.37
∆T 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11
kW 1.76 1.79 1.85 1.91 1.90 1.94 2.00 2.07 2.02 2.07 2.14 2.21 2.13 2.18 2.25 2.33 2.22 2.27 2.35 2.43 2.30 2.36 2.44 2.52
Amps 7.5 7.7 7.9 8.2 8.1 8.3 8.5 8.8 8.7 8.9 9.2 9.5 9.3 9.5 9.8 10.2 9.9 10.1 10.4 10.8 10.4 10.7 11.0 11.4
Hi PR 212 228 240 251 237 256 270 281 270 291 307 320 308 331 350 365 346 372 393 410 382 411 434 453
Lo PR 104 111 121 129 110 117 128 136 114 121 133 141 120 128 139 148 126 134 146 155 130 138 151 161
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions kW = Total system power
High & low pressures are measured at the liquid & sucon access ngs. Amps = outdoor unit amps (comp.+ fans)