User Guide

10
PRODUCT DESIGN
LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE
GMVC950453BX*
GMVC950704CX*
AMVC950453BX*
AMVC950704CX*
-0.10 -0.10 20197308 -0.30 -0.75 11177113 -0.10 -0.10 -0.22 -0.55
HAPS28
11177115
GMVC950905CX*
AMVC950905CX*
-0.10 -0.10 0130F00070 -0.60 -1.70 0130F00111 N/A N/A N/A N/A N/A
GMVC950905DX*
GMVC951155DX*
AMVC950905DX*
AMVC951155DX*
-0.10 -0.10 20197308 -0.50 -1.10 11177114 -0.10 -0.10 -0.38 -0.82
HAPS29
11177116
GCVC90704CX*
ACVC90704CX*
-0.37 -0.37 20197313 -0.20 -0.55 11177118 -0.37 -0.37 -0.15 -0.30 HAPS31
GCVC950714CX*
ACVC950714CX*
-0.10 -0.10 0130F00070 -0.80 -1.60 0130F00100 N/A N/A N/A N/A N/A
GCVC90905DX*
ACVC90905DX*
-0.37 -0.37 20197313 -0.20 -0.55 11177118 -0.37 -0.37 -0.15 -0.30 HAPS31
GCVC950915DX*
ACVC950915DX*
-0.10 -0.10 0130F00070 -0.80 -1.60 0130F00100 N/A N/A N/A N/A N/A
GCVC91155DX*
-0.37 -0.37 20197313 -0.20 -0.55 11177118 -0.37 -0.37 -0.15 -0.30 HAPS31
PRESSURE SWITCH TRIP POINTS AND USAGE CHART
Note:
All installations above 7,000 ft. require a pressure switch change. For installations in Canada the *MVC95 & *CVC9/95 furnaces are certified only to 4500 ft.
TRIP POINT
COIL COVER
PRESSURE SWITCH
TRIP POINT
COIL COVER
PRESSURE SWITCH
TRIP POINT
ID BLOWER
PRESSURE SWITCH
COIL COVER
PRESSU RE
SWITCH
PART #
Note:
Replacement pressure switch number is listed below high altitude kit number.
Note:
All negative pressure readings are in inches of water column (" w.c.).
0 to 7,000 ft.
MODEL
TRIP POINT
ID BLOWER
PRESSURE SWITCH
HIGH
ALTITUDE
KIT
7,001 ft. to 11,000 ft.
ID BLOWER
PRESSURE
SWITCH