User's Manual

15
Basic command class
When door/window is opened, the will send Basic SET
command contains a value that is adjustable, to the node of
group2. For instance, a lamp module will be turned off after
receiving the BASIC_SET command.
Magnets to be opened:
[Command Class Basic , Basic Set, Basic Value = 0xFF]
Magnets to be closed:
[Command Class Basic , Basic Set, Basic Value = 0x00]
Con guration command class
This class is used for setting certain vendor speci c
con guration variables to the node of group2.
See the following table for con guration variables:
Id Name Size Range Default
value
Description
0x01 Basic Set level 1 bytes 1– 99 99 Ex: 1~99
1. ON (Binary
switch device)
2. Dim Level
(Multilevel
switch device)
0x02 Delay time
before the OFF
command be
transmitted
1 bytes 0 – 127 0s 0– 127: seconds